109
APPENDIX
Ack
[p][ ][Set ID][ ][OK/NG][Data][x]
1199.. AAbbnnoorrmmaall SSttaattee ((CCoommmmaanndd 22 :: zz))
GTo recognize an abnormal state.
Transmission
Data FF : Read
Data 0: Normal (Power on and signal exist)
1: No signal (Power on)
2: Turn the monitor off by remote control
3: Turn the monitor off by sleep time function
4: Turn the monitor off by RS-232C function
5: 5V down
6: AC down
7: Turn the monitor off by Fan Alarm function
8: Turn the monitor off by Off time function
9: Turn the monitor off by Auto sleep function
* This function is “read only”.
[k][z][ ][Set ID][ ][FF][ ][Cr]
Ack
[z][ ][Set ID][ ][OK][Data][x]
2200.. IISSMM MMeetthhoodd
((CCoommmmaanndd 11 :: jj,, CCoommmmaanndd 22 :: pp))
GTo control the ISM method. You can also adjust ISM
Method in OPTION menu.
It’s not available to use this function in LCD TV models.
Transmission
2211.. LLooww PPoowweerr
((CCoommmmaanndd 11 :: jj,, CCoommmmaanndd 22 :: qq))
GTo reduce the power consumption of the set. You can
also adjust Low Power in OPTION menu.
It’s not available to use this function in LCD TV models.
Transmission
Data 0 : Off
1 : On
[j][q][ ][Set ID][ ][Data][ ][Cr]
Ack
[q][ ][Set ID][ ][OK/NG][Data][x]
** RReeaall ddaattaa mmaappppiinngg 11
0 : Step 0
A : Step 10 (Set ID 10)
F :Step 15 (Set ID 15)
10: Step 16 (Set ID 16)
64: Step 100
6E: Step 110
73: Step 115
74: Step 116
C7: Step 199
FE : Step 254
FF : Step 255
** RReeaall ddaattaa mmaappppiinngg 22
0:-40
1:-39
2:-38
28 : 0
4E : +38
4F : +39
50 : +40
Data 0: Normal
1: White wash
2: Orbiter
3: Inversion
Ofrecido por www.electromanuales.com
Downloaded From TV-Manual.com Manuals