OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS) POSSIBLE AREAS OF
MISADJUSTMENT(S) RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING & REPAIR
F-6 F-6
POWER WAVE 655/R
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CAUTION
Major physical or electrical damage
is evident when the sheet metal
covers are removed.
Contact your local authorized
Lincoln Electric Field Service
Facility for technical assistance.
Contact the Lincoln Electric Service
Department at 1-888-935-3877
The input fuses repeatedly fail or
the input circuit breakers keep trip-
ping.
1. Make certain the fuses or break-
ers are properly sized.
2. Make certain the reconnect
panel is configured properly for
the applied voltage.
3. The welding procedure may be
drawing too much input current
or the duty cycle may be too
high. Reduce the welding cur-
rent and/or reduce the duty
cycle.
1. Check the reconnect switches
and associated wiring. See the
Wiring Diagram.
2. Perform the Input Rectifier
Test.
3. Perform the Switch Board
Test.
4. Perform the Input Contactor
Test.