CONNECTION OF LN-8 OR LN-9 TO THE DC-600 VRD POWER SOURCE

F-7

14-PIN RECEPTACLE

POWER SOURCE

21

 

 

CONTROL CABLE

 

 

 

 

 

FOR CONTROL CABLE

 

 

 

WITH 14 PIN

MS-TYPE

 

 

 

PLUG CONNECTOR

 

TO LN-8 OR LN-9

OR

 

N.F.

INPUT CABLE PLUG

 

 

 

 

FOR CONTROL CABLE

CONTROL

CABLE

WITH TERMINAL STRIP

 

 

 

LEAD CONNECTORS

Do not operate with covers removed.

Disconnect power source before servicing.

Do not touch electrically live parts.

Only qualified persons should install, use or service this machine.

 

 

 

 

 

 

 

 

 

 

 

N.A. Welding cables must be of proper capacity for the current and

 

 

 

 

 

 

 

 

 

 

 

duty cycle of immediate and future applications.

 

+21 - 21

41

4

2

31 32

75

76

77

 

 

N.B. Extend lead #21 from control cable with terminal strip connectors or

 

N.E.

 

from 14-pin receptacle using #14 AWG or larger insulated wire

 

 

 

 

 

 

 

 

 

 

 

physically suitable for the installation. An S16586-[LENGTH]

IDEALARC®

 

 

 

 

 

 

 

 

 

 

remote voltage sensing work lead may be ordered for this purpose.

N.G.

 

 

 

 

 

 

 

C

N.E.

Connect it directly to the work piece keeping it electrically

 

 

 

 

 

 

 

 

 

B

separate from the welding work lead circuit and connection. For

 

 

 

 

 

 

 

 

 

A

 

convenience, this extended #21 lead should be taped to the

 

 

 

 

 

 

 

 

 

32

 

welding work lead. (If the length of work lead circuit is

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

 

 

 

2

 

short, and connections can be expected to be reliable, then

 

N.B. & N.C.

 

 

 

 

4

 

control cable lead #21 does not need to be extended and can be

DC-

 

 

 

 

GND

 

directly connected to terminal #21 on the terminal strip. Note

NEGATIVE

 

 

POSITIVE

 

 

 

N.D.

 

that this is not the preferred connection because it adds error

600

 

 

 

 

 

 

to the wire feeder voltmeter reading.)

 

 

 

 

 

 

 

 

 

21

 

N.C. Tape up bolted connection if lead #21 is extended.

VRD

 

 

N.H.

 

 

 

 

 

 

N.D. Connect the control cable ground lead to the frame terminal

 

 

 

 

 

 

 

 

 

marked

near the power source terminal strip. The power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE CABLE

 

source grounding terminal (marked

and located near the power

 

 

 

 

 

 

 

 

 

 

source input power connections) must be properly connected to

 

 

 

 

 

 

 

 

 

TO WIRE FEED UNIT

 

electrical ground per the power source operating manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.A.

 

 

 

 

 

 

N.E. If using an older LN-8 control cable: connect lead #75 to #75 on

 

 

 

 

 

 

 

 

 

 

 

terminal strip, connect lead #76 to #76 on terminal strip, connect

 

 

 

 

 

 

 

 

 

 

 

lead #77 to #77 on the terminal strip.

 

 

 

 

 

 

 

 

 

 

TO WORK

 

N.F. The LN-9 voltage control jumpers must be connected as follows

 

 

 

 

 

 

 

 

 

 

 

(refer to LN-9 Operating Manual):

 

DIAGRAMS

REMOTE VOLTAGE SENSING LEAD

Above diagram shows electrode connected positive. To change polarity,

turn power off, reverse the electrode and work leads at the power source and position the switch on wire feeder (if equipped )

to proper polarity. Also refer to note N.F.

For proper setting of switches on power source, see power source operating manual.

White jumper on voltage board to pin "S" . Blue jumper on voltage board (later units only),

or on start board (earlier units), to pin "B".

N.G. If lead #21 is to be connected to the terminal strip, connect to

the #21 terminal that matches work polarity. This connection must be changed whenever the electrode polarity is changed.

N.H. Illustration does not necessarily represent actual position of appropriate output studs. Refer to power source instruction manual for more info.

10-30-98F

S22977

F-7

Page 47
Image 47
Lincoln Electric IM10018-A manual Connection of LN-8 or LN-9 to the DC-600 VRD Power Source