Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
|
| TROUBLESHOOTING & REPAIR |
POWER WAVE CURRENT TRANSDUCER
REMOVAL AND REPLACEMENT (CONTINUED)
FIGURE F.26 – POWER WAVE CURRENT TRANSDUCER REMOVAL AND REPLACEMENT PROCEDURE
CURRENT
TRANSDUCER
HEAVY LEAD
BOLTED CONNECTION (BEHIND CASE FRONT)
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
REMOVAL PROCEDURE
1.Remove input power to the Power Wave 455/R.
2.Using the 3/8” nut driver, remove the case top and sides and the control box cover.
3.Perform the Capacitor Discharge proce- dure.
4.Using the 3/8” socket wrench or nut driver, remove the three screws along the bottom case front. See Figure F.26.
5.Using the 3/8” socket wrench, remove the four screws that hold the case front to the machine.
6.Label all leads to all output terminals. Using the 5/16” wrench and the 3/4” wrench, remove all leads from the three output termi- nals. See the Wiring Diagram.
7.Cut any necessary cable ties. Then careful- ly swing the front panel aside.
8.Remove the insulating tape from the heavy lead bolted connection. See Figure F.26. Using the 9/16” wrenches, remove the bolt, lock washer and nut.