Lincoln Electric SVM 113-A service manual Normal Open Circuit Voltage Waveform 115 VAC Supply

Models: SVM 113-A

1 106
Download 106 pages 31.95 Kb
Page 70
Image 70

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-32

F-32

TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

1 Period = 16.2 ms @ 3700 rpm

CH1

0 volts

50 volts

5 ms

This is the typical AC output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine 115 VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

WELDANPOWER 125

Page 70
Image 70
Lincoln Electric SVM 113-A service manual Normal Open Circuit Voltage Waveform 115 VAC Supply