![](/images/backgrounds/41372/41372-11x1.png)
|
| 1. SENSOR & MAGNET DETAIL |
| 2. SET SENSOR SWITCH |
| 3. EXAMPLE SENSOR LOCATIONS | |||
| SENSOR HAS |
|
|
| SENSOR | ||||
| MAGNET CAN ACTIVATE SWITCH UP TO 1/2" AWAY. |
|
|
| |||||
|
|
| WHEN MOUNTING SENSOR, ALIGN MAGNET TO NOTCH. |
|
|
| ON FRAME | ||
|
|
|
|
|
| MAGNET | |||
|
|
| REMOVE PLASTIC BATTERY TAB |
|
|
| ON DOOR | ||
DOOR/WINDOW |
|
|
|
|
| ||||
| PRIOR TO INSTALLATION BY |
|
|
|
|
| |||
SENSOR |
|
| PULLING STRAIGHT OUT |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
For Use with |
|
|
|
| SENSOR |
|
|
|
|
Security Console |
|
| NOTCH ON |
|
|
|
|
| |
|
|
| SIDE OF |
|
|
|
|
|
|
Installation |
|
| SENSOR |
|
|
|
|
|
|
|
| ALIGN MAGNET |
|
| SET SWITCH TO DELAYED |
|
|
| |
Instructions |
|
|
|
| FOR ENTRY/EXIT DOOR |
|
|
| |
|
| NEXT TO NOTCH |
|
| SET SWITCH TO INSTANT |
|
|
| |
|
|
| ON SENSOR |
|
|
|
|
| |
|
|
|
|
| FOR WINDOWS OR |
|
|
| |
|
|
|
|
|
|
|
| MAGNET | |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ON WINDOW |
(760) | MAGNET | 1/2" SPACE |
|
|
| SENSOR | |||
|
|
|
| ||||||
www.linearcorp.com |
| MAXIMUM |
|
|
|
| ON FRAME | ||
4. PROGRAM SENSOR INTO CONSOLE | 5. EXAMPLE SENSOR MOUNTING ON DOOR | 6. EXAMPLE SENSOR MOUNTING ON WINDOW | 7. OPTIONAL MAGNET SPACER | ||||||
START IN |
| SEND SIGNAL |
|
|
|
|
|
|
|
OFF MODE |
| FROM SENSOR |
|
|
|
|
|
| USE SPACER WHEN |
|
|
|
|
|
|
|
|
| |
ENTER YOUR | PRESS | ENTER AN |
|
|
| MOUNT SENSOR |
|
| SURFACES ARE |
SECRET CODE | LEARN | UNUSED SENSOR |
|
|
| ALIGN MAGNET |
| UNEVEN | |
|
| NUMBER |
|
|
| PLATE TO FRAME |
|
| |
|
|
|
|
|
|
| PLATE NEXT TO |
|
|
LEARN BUTTON |
|
|
|
| SENSOR PLATE |
|
| ||
|
|
|
| AND ATTACH TO |
|
| |||
|
|
|
|
|
| SPACE BELOW |
|
| |
|
|
|
|
|
| WINDOW |
|
| |
|
|
| MOUNT SENSOR |
|
| PLATE IS REQUIRED |
|
|
|
|
|
|
|
| TO SNAP SENSOR |
|
|
| |
|
|
| PLATE TO FRAME |
|
|
|
|
| |
|
|
|
|
| ONTO PLATE |
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| HOOK SPACER TO |
|
|
| 1/2" MAXIMUM |
|
| 1/2" MINIMUM |
|
| MAGNET PLATE |
|
|
|
|
|
|
| AND ROTATE TO | ||
|
|
| SPACE BETWEEN |
|
|
|
|
| LOCK IN PLACE |
1 |
|
| SENSOR AND |
|
|
|
|
| |
|
|
|
| ALIGN MAGNET |
|
|
|
| |
|
|
| MAGNET PLATES |
|
|
|
|
| |
|
|
|
|
| PLATE NEXT TO | SNAP SENSOR ONTO |
|
| R&TTE VAEE 28357, EMC, SFT, ETS |
PRESS SENSOR |
|
|
|
| SENSOR PLATE |
|
| ||
|
|
|
| MOUNTING PLATE |
|
|
| ||
OR MOVE MAGNET |
| HOLD OFF BUTTON | SNAP SENSOR ONTO |
| AND ATTACH TO |
|
| Linear Corporation declares that the apparatus | |
TO SEND SIGNAL |
| FOR 3 SECONDS WHEN |
| DOOR |
|
|
| ||
| MOUNTING PLATE |
|
|
|
| ||||
|
| FINISHED TO EXIT |
|
|
|
|
| complies with the essential requirements and other relevant | |
|
|
|
|
|
|
|
| ||
|
| LEARN MODE |
|
|
|
|
|
| provisions of Directive 1995/5/EC. |
8. TEST SENSOR |
|
| 9. LABEL SENSORS |
| 10. CHANGING BATTERIES |
|
| INTERNATIONAL WARRANTY | |
|
|
| STATUS INDICATOR |
|
|
|
| This Linear product is warranted against defects in material and workmanship for twelve (12) months. The | |
|
|
|
|
| WHEN CONSOLE INDICATES A SENSOR | Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who | |||
|
|
| SHOULD LIGHT |
|
| ||||
SENSOR LIGHT |
|
|
|
| buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product | ||||
|
| WHEN SENSOR IS OPEN |
|
| LOW BATTERY, OPEN SENSOR CASE AND | to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if | |||
SHOULD |
| OPEN DOOR |
|
|
| GENTLY LIFT UP END OF BATTERY CLAMP, | any. There are no obligations or liabilities on the part of Linear Corporation for consequential damages | ||
|
|
|
| arising out of or in connection with use or performance of this product or other indirect damages with | |||||
GLOW FOR |
|
|
|
| SLIDE BATTERIES OUT | ||||
| OR WINDOW |
|
|
| respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied | ||||
TWO SECONDS |
|
|
|
|
|
| warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until | ||
|
|
|
|
|
|
| Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other | ||
|
|
|
|
|
|
|
| warranties express or implied. | |
|
|
|
|
|
| NOTE: USE OF EXCESSIVE FORCE ON | For | warranty service on Linear equipment return product, at sender’s expense to: Linear Hong Kong | |
|
|
|
|
|
| BATTERY CLAMP WILL RESULT IN DAMAGE | 19/F | Hounor Industrial Centre,6 Sun Yip Street Chai Wan, Hong Kong Attention: Repairs Department | |
|
|
| 1 |
|
| REPAIRS POLICY | |||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| Charges will be made for equipment that is not of warranty, shows customer abuse, or is damaged by the effects | |
|
|
|
|
|
|
| + | of lightning, water, fi re, or other abnormal happenings. | |
|
|
|
|
|
|
| Customer’s equipment sent in for repair may be repaired or replaced with new or remanufactured equipment | ||
|
|
|
|
|
|
| - | at Linear’s discretion. | |
|
|
|
|
|
|
| The customer is always responsible for shipping and handling charges to the repairs facility. Linear will pay return | ||
|
|
|
| USE LABELS PROVIDED | LIFT | + | shipping and handling charges on “in warranty” products shipped back to the customer. The customer will be | ||
|
|
|
| billed for the return shipping and handling charges on “out of warranty” products. | |||||
|
|
|
| TO IDENTIFY SENSORS |
| - | |||
|
|
|
|
| There will be a 50% expedite fee for any express requests. | ||||
|
|
|
|
|
|
| INSTALL TWO | The International Sales Manager must be notifi ed prior to the return of product to Linear. All international returns | |
|
|
|
|
|
|
| must have an International Repair Authorization number (IRA#). The number must be marked on all packages. | ||
|
|
|
|
|
|
| DURACELL | Failure to do so will cause delays in processing. | |
|
|
|
|
|
|
| TYPE DL 2032 | IMPORTANT !!! | |
|
|
|
|
|
|
| Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless | ||
|
|
|
|
|
|
| BATTERIES (+) | ||
|
|
|
|
|
|
| signaling. However, there are some limitations which must be observed. | ||
CONSOLE IN |
|
|
|
|
|
| SIDE UP | The radios are required to comply with local rules and regulations as radio devices. As such, they have limited | |
|
|
|
|
|
|
| transmitter power and therefore limited range. | ||
CHIME MODE |
|
|
|
|
|
|
| A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that | |
|
|
|
|
|
| REMOVE BATTERIES | occur on or near their operating frequencies, regardless of code settings. | ||
SHOULD |
|
|
|
|
| IF NECESSARY | FROM THIS END | Changes or modifi cations to the device may void regulatory compliance. | |
|
|
|
|
| Infrequently used radio links should be tested regularly to protect against undetected interference or fault. | ||||
|
|
|
|
|
| PUSH IN SLOT TO REMOVE |
| A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or | |
|
|
|
|
|
| SENSOR FROM MOUNTING PLATE |
| dealer, and these facts should be communicated to the ultimate users. |
Copyright © 2003 Linear Corporation | 220837 A |