MDR-U

 

 

 

 

CAUTION

 

 

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

 

 

 

 

RISK OF ELECTRICAL SHOCK

 

 

 

WARNING

1.

 

Read these instructions.

 

 

 

 

 

 

 

 

 

2.

 

Keep these instructions.

 

 

 

 

 

 

DO NOT OPEN

 

 

TO REDUCE THE RISK OF SEVERE

3.

 

Heed all warnings.

 

Universal

 

 

 

 

 

 

5. Do not use this apparatus near water.

MegaCode

 

 

 

 

 

 

 

INJURY OR DEATH

4.

 

Follow all instructions

 

 

 

 

 

 

 

 

6. Clean only with dry cloth.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Receiver

 

 

 

EXPLANATION OF GRAPHIC WARNING SYMBOLS

 

1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS

 

7.

Do not install near any heat sources such as radiators, heat registers, stoves, or other

 

 

 

Thissymbol is intended to alert the userto the presence

of

2. NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN!

 

 

apparatus (including amplifi ers) that produce heat.

 

 

 

8.

 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized

 

 

 

 

un-insulated “dangerous voltage” within the product’s enclosure that

3. ALWAYS KEEP MOVING DOOR IN SIGHT AND AWAY FROM PEOPLE AND OBJECTS UNTIL IT IS COMPLETELY CLOSED.

 

 

 

 

 

 

 

plug has two blades with one wider than the other. A grounding type plug has two

For Garage Door Operator

 

 

may be of suffi cient magnitude to constitute a risk of electric shock.

NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

 

 

 

 

 

 

 

 

blades and a third grounding prong. The wide blade or the third prong are provided for

Remote Control

 

 

 

WARNING! To reduce the risk of fire or electric shock, do not

4. NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

 

 

 

 

 

 

 

 

 

your safety. If the provided plug does not fi t into your outlet, consult an electrician for

 

 

 

 

expose this device to rain, water, or wet locations.

 

 

 

CAUTION

 

 

Installation Instructions

 

of

 

 

9.

Unplug this apparatus during lightning storms or when unused for long periods of time.

 

This

symbol is intended to alert the user

to the presence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replacement of the obsolete outlet.

 

 

 

 

important operating and maintenance (Servicing) instructions in the

TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT POWER TO THE RECEPTACLE BEFORE INSTALLING OR

10. Refer all servicing to qualifi ed service personnel. Servicing is required when the

 

 

 

 

literature accompanying the device.

 

 

 

 

 

 

 

 

REMOVING THE UNIT. WHEN REMOVING RECEPTACLE COVER SCREW, COVER MAY FALL ACROSS PLUG PINS OR

 

 

apparatus has been damaged in any way, such as power-supply cord or plug is

 

 

 

 

 

 

 

 

 

 

 

(760) 438-7000 • FAX (760) 438-7043

 

 

 

 

 

RECEPTACLE MAY BECOME DISPLACED. USE ONLY WITH DUPLEX RECEPTACLE HAVING CENTER SCREW. SECURE UNIT

 

 

damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus

 

USA & Canada (800) 421-1587 & (800) 392-0123

 

 

 

 

IN PLACE BY RECEPTACLE COVER SCREW.

 

 

 

has been exposed to rain or moisture, does not operate normally, or has been dropped.

 

Toll Free FAX (800) 468-1340

 

 

 

 

 

 

 

 

 

www.linearcorp.com

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT DESCRIPTION

 

 

COMPONENT LOCATIONS

 

 

DETERMINE THE BEST RECEIVER LOCATIONCHECK FOR INTERFERENCE FROM OTHER RECEIVERS
The Model MDR-U Universal MegaCode™ Receiver is designed for use as a

 

AC POWER

 

 

 

 

 

BEST

 

 

WATCH THE

 

replacement radio control receiver ingarage dooroperator installations. TheRETAININGTERMINALS

 

 

 

 

 

 

 

IF THE LEARN INDICATOR IS FLASHING
LEARN & SIGNAL

 

 

 

 

RECEPTION

 

 

MDR-U RECEIVER'S

receiver is self-contained, not requiring an external transformer or power from the

SCREW

 

INDICATOR

 

 

 

A PLUG ON THE CEILING WILL GIVE THE BEST RADIO

 

 

LEARN INDICATORWITHOUT ACTIVATING ANY TRANSMITTERS,

 

 

 

 

 

 

INTERFERENCE MAY BE COMING FROM

 

 

 

 

 

 

 

garage door operator. The receiver plugs directly into a 120 VAC outlet. A retaining

 

 

 

 

 

 

RECEPTION (UNLESS THE OPERATOR'S RECEIVER

 

 

 

A NEARBY OPERATOR'S RECEIVER

 

 

 

 

 

 

CAUSES SOME INTERFERENCE)

 

 

 

screw is provided to secure the receiver to the outlet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two screw terminals on the receiver are for connection to the garage operator’s

 

 

 

 

 

 

 

 

 

 

 

 

pushbutton input. A dry contact, Form “A”, relay in the receiver will provide a

 

 

 

 

 

 

 

 

 

 

 

TEST IF THE OPERATOR IS THE SOURCE OF THE

.5-seconds closure across the terminals when the receiver activates. A fl exible wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GOOD

 

 

 

INTERFERENCE BY UN-PLUGGING THE OPERATOR FROM

antenna extends from the receiver’s case to provide maximum radio reception.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

RECEPTION

 

 

 

MegaCode™ receivers and transmitters do not contain a typical “coding switch”.

 

 

 

 

 

 

 

 

 

 

IF THE LEARN INDICATOR STOPS FLASHING, THE OPERATOR

 

 

 

 

 

 

 

 

 

 

 

Each transmitter is pre-set at the factory to a unique code. The receiver is

 

 

 

 

 

 

 

 

 

 

 

IS THE SOURCE OF INTERFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

programmed by sending a signal from the transmitter, storing the transmitter’s code

 

 

 

 

 

 

 

A PLUG ABOVE

 

 

 

1. IF THE OPERATOR HAS AN EXTERNAL RADIO RECEIVER,

into the receiver’s memory. The receiver will retain its memory, even without power.

 

 

 

 

 

 

 

 

 

 

DISCONNECT POWER TO IT

 

 

 

 

 

 

A PLUG CLOSETHE GROUND LEVEL

 

 

 

 

The receiver will activate only from these “memorized” transmitters. Each MDR-U

 

 

 

 

 

 

 

 

 

2. IF THE OPERATOR HAS A BUILT-IN RADIO RECEIVER, CUT

 

 

 

 

 

 

WILL PROVIDE

 

 

 

 

 

 

 

 

 

TO GROUND LEVEL

 

 

OPERATOR'S

THE COMPONENT THAT FEEDS POWER TO THE RECEIVER

receiver can be programmed to activate from up to ten MegaCode™ transmitters.

 

 

 

 

POOR

 

GOOD RADIO

 

 

ANTENNA

 

 

 

 

WILL CAUSE

 

 

OR CUT OFF THE OPERATOR'S ANTENNA AND REMOVE THE

The learn button andlearn indicatorare used forentering and erasing theRELAY OUTPUTLEARN

 

RECEPTION

POOR RADIORECEPTION

 

 

ANTENNARECEIVER'S TUNING SLUG

 

 

RECEPTION

 

 

 

 

 

transmitters in the receiver’s memory. The learn indicator also displays signals

 

TERMINALSBUTTON

 

 

 

 

NOTE: IT IS RECOMMENDED TO DISABLE THE OPERATOR'S

 

1 AMP @ 32 VDC

 

 

 

 

 

 

 

 

 

 

 

 

being received and can be used for troubleshooting.

 

 

MAXIMUM

 

 

 

 

 

 

RECEIVER TO PREVENT THE OLD REMOTES FROM ACTIVATING IT
CONNECT THE RECEIVER TO THE OPERATORINSTALL THE RECEIVER

 

 

PROGRAM AND TEST THE RECEIVER

 

 

LINEAR LIMITED WARRANTY
CONNECT 2-CONDUCTOR WIRE TO THE

 

 

 

 

 

 

 

ADDING TRANSMITTERSERASING TRANSMITTERS

This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty

DISCONNECT POWER TO THE GARAGE

 

REMOVE THE OUTLET'S COVER

 

 

 

Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct

 

 

 

 

1. PRESS AND RELEASE THE1. PRESS AND HOLD DOWN THE LEARN BUTTON
MDR-U RECEIVER RELAY OUTPUT TERMINALSDOOR OPERATOR BEFORE PROCEEDING

 

 

 

 

from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers.

 

PLATE SCREW AND PLUG THE

 

 

 

LEARN BUTTON

 

 

 

 

 

 

 

 

 

 

 

2. THE LEARN INDICATOR WILL

Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no

 

 

UL NOTE: ALL LOW VOLTAGE CLASS 2 CABLE

 

RECEIVER INTO THE 110 VAC OUTLET

 

 

 

 

 

 

 

 

 

 

 

2. THE LEARN INDICATOR WILL LIGHT

obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in

 

 

USED WITH THE OPERATOR MUST BE UL LISTED

 

 

 

 

 

FLASH COUNTING THE NUMBER

 

 

 

 

 

 

 

connection with use or performance of this product or other indirect damages with respect to loss of property,

 

 

TYPE CL2, CL2P, CL2R, OR CL2X OR OTHER CABLE

 

 

 

 

 

IF THERE'S ROOM IN MEMORYOF TRANSMITTERS IN MEMORY

 

 

 

 

 

 

 

revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied

 

 

 

 

 

 

 

(UP TO 10 TRANSMITTERS WILL FIT)

 

 

 

WITH EQUIVALENT OR BETTER ELECTRICAL,

 

 

 

 

 

 

 

 

 

NOTE: BE SURE THAT THE OUTLET

 

 

 

 

3. CONTINUE HOLDING DOWN

warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled

 

 

MECHANICAL, AND FLAMMABILITY RATINGS

 

 

 

 

 

 

 

 

IS NOT CONTROLLED BY A WALL SWITCH

 

3. ACTIVATE THE TRANSMITTERTHE LEARN BUTTON

on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHILE THE INDICATOR IS LIT

 

All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear

 

 

 

WALL PUSHBUTTON

 

 

 

 

 

(WITHIN 15 SECONDS)4. 5 SECONDS AFTER THE COUNTTechnical Services at 1-800-421-1587 for an RPA# and other important details.
ROUTE THE WIRE AND CONNECT IT

 

CONNECTION

 

 

 

 

 

4. INDICATOR FLASHESTHE INDICATOR WILL FLASH ONCE

 

 

 

IMPORTANT !!!

 

 

 

 

 

 

SHOWING THE MEMORY ERASURE

 

 

 

TO EITHER THE WALL PUSHBUTTON ORFROM

 

 

 

 

 

Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling.

 

 

 

 

 

 

 

 

DIRECTLY TO THE DOOR OPERATOR

 

OPERATOR

 

 

 

 

 

5. REPEAT STEPS FOR ADDITIONAL5. RELEASE THE BUTTON, THE UNITHowever, there are some limitations which must be observed.
(POLARITY NOT IMPORTANT)

 

 

 

 

 

 

 

TRANSMITTERS

 

ENTERS LEARN MODE FOR 15 SECONDS

• For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As

DIRECT OPERATORSECURE THEPUSHBUTTON

 

 

 

 

 

 

 

 

 

such, they have limited transmitter power and therefore limited range.
WIRE WITHMDR-U

 

 

 

 

 

 

 

 

• A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that

CONNECTION

 

INSULATED

 

 

 

 

 

 

 

 

 

occur on or near their operating frequencies, regardless of code settings.

 

 

SECURE THE RECEIVER

 

 

 

 

 

 

 

 

 

STAPLES

 

 

 

 

 

 

 

• Changes or modifi cations to the device may void FCC compliance.

 

 

 

 

TO THE OUTLET WITH

 

 

 

 

 

 

• Infrequently used radio links should be tested regularly to protect against undetected interference or fault.

 

 

 

 

THE RETAINING SCREW

 

 

TEST RECEIVER

 

 

• A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer,

 

 

 

 

 

 

 

 

 

 

 

and these facts should be communicated to the ultimate users.

 

 

 

 

 

 

 

 

ACTIVATE EACH TRANSMITTER

 

 

 

 

 

 

ANTENNA

 

 

 

 

 

 

• This device complies with FCC Part 15 and Industry Canada Rules and Regulations. Operation is subject to the following two

3 2 1

OPERATOR TERMINALS 1 & 2

 

 

 

 

AND VERIFY THAT THE RECEIVER

 

 

 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,

 

 

 

 

 

 

 

 

 

(OR THE SAME TERMINALS

 

 

 

 

 

AND DOOR OPERATOR ACTIVATES

 

 

 

including interference that may cause undesired operation.

 

 

 

 

 

 

 

 

 

 

 

 

THE WALL PUSHBUTTON USES)

 

 

 

 

 

 

 

 

 

Copyright © 2004 Linear Corporation

220675 A