MegaCode Series

 

 

 

 

 

DESCRIPTION

 

 

 

MDR, MDR2, MDRNR,

 

 

 

 

The MegaCode series of digital receivers are wireless radio

 

 

 

 

controls designed for use with automatic garage door and gate

MDRM, MDRM2

 

 

 

 

 

openers. The MegaCode radio format provides unparalleled

 

 

 

 

 

security. The transmitter and receiver can be programmed to more

DIGITAL RECEIVERS

 

 

 

 

 

 

 

 

than a million different codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MegaCode receivers and transmitters do not contain a typical

 

 

 

 

 

 

 

 

“coding switch”. Each transmitter is pre-set at the factory to a

 

 

 

 

 

 

 

 

unique code. The receiver is programmed by sending a signal to

Installation Instructions

 

 

 

 

it from the transmitter(s) that are going to be used with it. This

 

 

 

 

stores the transmitters code into the receiver’s memory. The

 

 

 

 

 

 

 

 

receiver will retain its memory even without power. The receiver

 

 

 

 

 

 

 

 

will activate only from these “memorized” transmitters. Each

 

 

 

 

 

 

 

 

MegaCode receiver can remember a maximum of 10

 

 

 

 

 

 

 

 

transmitters.

 

 

 

 

 

 

 

 

 

 

 

Receivers are normally powered with 24 volts AC/DC from the garage

 

 

 

 

 

 

 

 

door or gate operator. Two-channel receivers provide wire

 

 

(800) 421-1587 www.linearcorp.com

 

connections to activate the operator’s light or control other devices.

 

 

 

 

 

 

 

 

 

STEP 1A
MDR/MDRNR/MDR2 Three-terminal Operator
STEP 1B

 

MDRM/MDRM2 Recessed Receiver Operator

Installation. Hold receiver up to back of operator. Connect

Installation. Loosen operator terminal screws. Install receiver

Terminals 1, 2 & 3 on the receiver to Terminals 1, 2 & 3 on the

into operator “pocket”. Connect Terminals 1, 2 & 3 on the receiver

operator.

 

 

 

 

 

 

to Terminals 1, 2 & 3 on the operator.

 

 

 

 

 

 

 

 

 

1

 

2

3

 

 

 

 

 

 

 

 

 

 

COMMON

RELAY

24-VOLTS

 

 

 

 

 

 

 

 

 

 

RADIO

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

 

3

2

1

 

 

 

 

1 2 3

 

COMMON

 

24-VOLTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

RADIO

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT

 

 

 

 

 

 

 

 

 

 

BRASS

 

 

RECEIVER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MATCH UP

 

 

 

 

 

TERMINALS

 

 

DIRECTLY

 

 

 

 

RECEIVER FITS INTO

 

FIT TO

 

 

 

 

 

 

TERMINAL

 

 

 

TO OPERATOR

 

 

 

 

TERMINALS

 

 

 

 

 

NUMBERS

BACK OF OPERATOR

ANTENNA

 

 

 

 

 

 

 

1, 2 AND 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEP 2 MDR2/MDRM2 Two-channel Receiver Installation.

STEP 3

Optional Receiver Mounting Bracket. If the receiver

Connect the receiver to the operator as described in the previous

isn’t going to be mounted directly to the operator terminals, an

step. The channel-two pigtail wires can be connected to the

optional mounting bracket is supplied. It can be installed three

operator’s light toggle terminals or to an external device.

ways onto the MDR or MDR2 case. Screw the bracket to a wall

BROWN

ORANGE

RED

CONNECT BROWN TO COMMON GROUND

or stud and snap the receiver onto it.

 

 

 

 

 

 

 

RELAY

RELAY

RELAY

CONNECT ORANGE TO LIGHT TERMINAL

 

 

 

 

 

 

NORMALLY

NORMALLY

BRACKET CAN

 

 

 

CORNER HOLE IS

COMMON

 

 

 

OPEN

CLOSED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND (#1)

MOUNT IN THREE

 

 

SHARED FOR

 

 

 

 

 

 

PLACES

 

 

 

 

LOCATIONS 2 & 3

 

 

 

 

 

 

 

 

 

 

 

 

 

LOCATION 2

 

 

 

LIGHT

 

 

 

 

LOCATION 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL

 

 

 

 

 

 

 

 

 

 

 

 

 

(#0)

 

 

 

 

 

 

 

 

 

 

 

 

 

3-TERMINAL

 

 

 

RECESSED RECEIVER

 

 

 

 

 

LOCATION 3

 

 

 

OPERATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MDR - Single-channel external receiver with relay output. MDRM - Single-channel internal receiver (fits operators with recessed receivers) with solid state output.

MDRNR - Single-channel external receiver with solid state output. MDR2 - Two-channel external receiver with relay outputs. MDRM2 - Two-channel internal receiver (fits operators with recessed receivers) with solid state output on channel one and relay output on channel two.

SINGLE

MDRM2

 

CHANNEL

 

 

MDRM

MDR

MDR2

TWO

MDRNR

CHANNEL

 

STEP 1C MDR/MDR2 Two-terminal Operator Installation.

The Model TF524 step-down transformer must be used to power the receiver when connecting to a two-terminal operator or one that supplies other than 24V. Install the screws supplied into the brass terminals on the receiver. Connect the transformer wires to Terminals 1 & 3 (polarity not important). Connect receiver Terminals 1 & 2 to the two operator terminals (polarity not important).

WIRE TERMINALS 1 & 2 TO OPERATOR

WIRE TRANSFORMER TO TERMINALS 1 & 3

PUSHBUTON TERMINALS

 

 

1

 

2

 

3

INSTALL 3 SCREWS

USE MODEL #TF524 24VAC, .5VA

TRANSFORMER

STEP 4A MDR/MDRNR/MDR2 Program button and LED Location. Locate the program button and LED on the side of the receiver case.

CHANNEL ONE

PROGRAMMING

BUTTON

PROGRAMMING

LED

CHANNEL TWO

PROGRAMMING

BUTTON (ONLY

ON MDR2)