Specifications
System:
Freq. Range
Freq. Response (±3 dB):
Horz. Coverage Angle
90°, averaged
Vert. Coverage Angle
70°, averaged
Directivity Factor Q (DI):
10.0 (10.0), averaged
System Sensitivity:
101 dB, 1W@1m
Rated Maximum SPL:
126 dB @ 1 m (3.3ft) peak
HF Protection:
Dynamic
Transducers:
Low Frequency:
12" (300 mm) diameter woofer
High Frequency:
Voice Equalization:
+4.0 dB @ 3kHz
+4.0 dB @ 6kHz
Indicators:
Power ON, Limiter
Amplifiers:
LF Amplifier Power:
300 watts RMS
HF Amplifier Power:
60 watts RMS
Distortion:
< 0.1% THD at rated power
Amp Protection:
Thermal, limiter, short circuit
Power Supply:
115/230 VAC, 2A, 50/60 Hz
Physical:
Enclosure:
Asymmetrical trapezoidal, reinforced polypropylene
Mounting:
Lockable
ART300A
Active Speaker System
Quick-Start Guide
The ART300A is a
It features a balanced XLR input with a Mic/Line switch and a paralleled balanced XLR output for cascading multiple speakers. Rear panel controls also include Music and Voice equalization switches, a rotary volume control, and an input limiter.
The two
1" (25 mm) compression driver, horn loaded
Preamp and Processor:
Input Sensitivity:
Mic In: 8mV
Line In: 125mV
Input Impedance:
Mic In: 650Ω unbalanced 1.3kΩ balanced
Line In: 10kΩ unbalanced 19kΩ balanced
Crossover Frequency and Slope: 1.8kHz; 24 dB/octave
Time Alignment:
Analog, 0.3 ms HF delay
Speaker Protection:
Thermal,
Music Equalization:
+4.3 dB @ 65Hz
+4.0 dB @ 12kHz
mount
Rigging Inserts:
4 points, accepts M10 threaded hardware
Input/Output Connectors: 2 XLR balanced
Dimensions HxWxD:
24.4" x 15.4" x 12.3"
(620 mm x 390 mm x 312 mm)
Net Weight:
44.0 lb (20.0 kg)
industrial@mackie.com
16220
UK +44.1268.570.808, FAX +44.1268.570.809
Safety First!
Before connecting and using the equipment, please read this
WARNING! This equipment has been designed to be installed by qualified professionals only! There are many factors to be considered when installing professional sound reinforcement systems, including mechanical and electrical considerations, as well as acoustic coverage and performance. Mackie Industrial strongly recommends that this equipment be installed only by a professional sound installer or contractor.
CAUTION: To avoid the risk of electric shock, never allow this equipment to be exposed to rain or dampness.
1.Never install, connect, or disconnect the unit with the power supply on.
2.Before powering up the speaker, make sure the voltage select switch corresponds to the AC Voltage supply.
3.Make sure the safety ground on the power cord is properly grounded.
4.To prevent the risk of electric shock, never open the unit. There are no user serviceable parts inside.
5.To ensure normal cooling of the amplifier, make sure the unit is well- ventilated. Avoid exposure to direct sunlight or proximity to any heat source, dust, or dampness.
Part No.
© 2000 Mackie Industrial. All Rights Reserved. Printed in the USA.