Quattro DC Quick Parameter Reference
Sub
menu Parameter Units Range Default
Site
Setting
A3 Multistep Ref A3 Submenu – See Multistep Ref A3 submenu on page 41.
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 1 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 2 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 3 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 4 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 5 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 6 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 7 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 8 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 9 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 10 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 11 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 12 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 13 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 14 m/sec -16.000 – +16.000 0.000
ft/min -3000.0 – +3000.0 0.0
A3 SPEED COMMAND 15 m/sec -16.000 – +16.000 0.000
A4 Motor Side Power Convert A4 Submenu – See Motor Side Power Convert on page 43.
A4 ARM RESISTANCE ohm 0.0001 – 2.9999 0.5000
A4 ARM INDUCTANCE mH 0.01 – 327.67 15.00
A4 MTR REV VLT LIM % 0.01 – 30.00 4.80
A4 If REG INT GAIN none 0.00 – 30.00 0.90
A4 If REG PROP GAIN none 0.00 – 16.38 6.07
A4 AUTO TUNE MOTOR none − Start Autotune? -
A4 GAIN SELECTION none − manual
− autotune MANUAL
A4 GAIN BANDWIDTH A rad/sec 100 – 2000 500
A4 GAIN BANDWIDTH F rad/sec 1 – 40 5
A4 PWM FREQUENCY kHz 2.5 – 16.0 6.0
A4 FAN OFF DELAY sec 0 – 999 180
A4 MAIN FAN CONTROL none
− auto
− temp
− off
− low
− medium
− high
TEMP
A4 UV-ALARM LEVEL % 80 – 99 90
A4 UV FAULT LEVEL % 50 – 99 80
A4 FLD CARRIER FRQ kHz 3 – 10 3
5