Maintenance Indicators

The warning lights (power indicator, lamp indicator and temperature warning indicator) on the projector indicate problems inside the projector.

If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate red, and the projector will enter standby mode. After the projector has entered standby mode, follow the procedures given below.

Top View

STANDBY/ON LAMP

TEMP.

INPUT

ENTER

Temperature warning indicator

Lamp indicator

Power indicator

ASPECTMENU

About the temperature warning indicator

If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,

” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will turn off and the temperature warning indicator will blink, the cooling fan will run, and then the projec-

tor will enter standby mode. After “” appears, be sure to perform the measures described on page 53.

About the lamp indicator

When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be displayed on the screen. When the percentage becomes 0%, it will change to (red), the lamp will automatically turn off and then the projector will automatically enter standby mode. At this time, the lamp indicator will illuminate in red.

If you try to turn on the projector a fourth time without replacing the lamp, the projector will not turn on.

Indicators on the Projector

Power indicator

Red on

Normal (Standby)

 

 

 

 

Green on

Normal (Power on)

 

 

 

 

Red blinks

Abnormal (See page 53.)

 

 

 

 

Green blinks

Normal (Cooling)

 

 

 

Lamp indicator

Green on

Normal

 

 

 

 

Green blinks

The lamp is warming up or shutting down.

 

 

 

 

Red on

The lamp is shut down abnormally or

 

 

requires to be changed. (See page 53.)

 

 

 

Temperature warning

Off

Normal

indicator

 

 

Red on

The internal temperature is abnormally

 

 

 

high. (See page 53.)

 

 

 

52