Parameter listParameter list
58
4
PARAMETERS Parameter List
30 Regenerative function selection 0, 1, 2 1 0 110,
136 30 1E 9E 0 
Frequency jump
31 Frequency jump 1A 0 to 400Hz, 9999 0.01Hz 9999 84 31 1F 9F 0   
32 Frequency jump 1B 0 to 400Hz, 9999 0.01Hz 9999 84 32 20 A0 0 
33 Frequency jump 2A 0 to 400Hz, 9999 0.01Hz 9999 84 33 21 A1 0   
34 Frequency jump 2B 0 to 400Hz, 9999 0.01Hz 9999 84 34 22 A2 0 
35 Frequency jump 3A 0 to 400Hz, 9999 0.01Hz 9999 84 35 23 A3 0   
36 Frequency jump 3B 0 to 400Hz, 9999 0.01Hz 9999 84 36 24 A4 0 
37 Speed display 0, 0.01 to 9998 0.001 0127 37 25 A5 0   
40 RUN key rotation direction selection 0, 1 1 0 237 40 28 A8 0 
Frequency
detection
41 Up-to-frequency sensitivity 0 to 100% 0.1% 10% 123 41 29 A9 0   
42 Output frequency detection 0 to 400Hz 0.01Hz 6Hz 123 42 2A AA 0 
43 Output frequency detection for reverse
rotation 0 to 400Hz, 9999 0.01Hz 9999 123 43 2B AB 0   
Second functions
44 Second acceleration/deceleration time 0 to 3600s 0.1s 5/10s ∗2 96, 220 44 2C AC 0 
45 Second deceleration time 0 to 3600s, 9999 0.1s 9999 96, 220 45 2D AD 0   
46 Second torque boost 0 to 30%, 9999 0.1% 9999 73 46 2E AE 0 ×
47 Second V/F (base frequency) 0 to 400Hz, 9999 0.01Hz 9999 85 47 2F AF 0×  
48 Second stall prevention operation
current 0 to 200%, 9999 0.1% 9999 79 48 30 B0 0 
51 Second electronic thermal O/L relay 0 to 500A, 9999 0.01A 9999 100 51 33 B3 0   
Monitor functions
52 DU/PU main display data selection
0, 5, 8 to 12, 14, 20,
23 to 25, 52 to 55, 61,
62, 64, 100
10128 52 34 B4 0 
55 Frequency monitoring reference 0 to 400Hz 0.01Hz 60Hz 133 55 37 B7 0   
56 Current monitoring reference 0 to 500A 0.01A
Rated
inverter
current
133 56 38 B8 0 
Automatic
restart
functions
57 Restart coasting time 0, 0.1 to 5s, 9999 0.1s 9999 136 57 39 B9 0   
58 Restart cushion time 0 to 60s 0.1s 1s 136 58 3A BA 0 
59 Remote function selection 0, 1, 2, 3 1 0 93 59 3B BB 0   
60 Energy saving control selection 0, 9 1 0 147 60 3C BC 0 ×
65 Retry selection 0 to 5 1 0 144 65 41 C1 0   
—66
Stall prevention operation reduction
starting frequency 0 to 400Hz 0.01Hz 60Hz 79 66 42 C2 0 
Retry
67 Number of retries at fault occurrence 0 to 10, 101 to 110 1 0 144 67 43 C3 0   
68 Retry waiting time 0.1 to 600s 0.1s 1s 144 68 44 C4 0 
69 Retry count display erase 0 1 0 144 69 45 C5 0   
70 Special regenerative brake duty 0 to 30% 0.1% 0% 110 70 46 C6 0 
71 Applied motor 0, 1, 3, 13, 23, 40, 43,
50, 53 1 0
75,
103,
105,
71 47 C7 0   
72 PWM frequency selection 0 to 15 1 1 148 72 48 C8 0 
73 Analog input selection 0, 1, 10, 11 1 1 150 73 49 C9 0 ×
74 Input filter time constant 0 to 8 1 1 152 74 4A CA 0 
75 Reset selection/disconnected PU
detection/PU stop selection 0 to 3, 14 to 17 114 158 75 4B CB 0 × ×
77 Parameter write selection 0, 1, 2 1 0 161 77 4D CD ∗4 0
78 Reverse rotation prevention selection 0, 1, 2 1 0 162 78 4E CE 0   
79 Operation mode selection 0, 1, 2, 3, 4, 6, 7 1 0 165,
175
79 4F CF ∗4 0
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code Control Mode-based
Correspondence Table Parameter
Read Write
Extended
Copy Clear
All clear
V/F
V/F
V/F
GP
MFVC
GP
MFVC
GP
MFVC