396
511 Parameter 6 for user 0B 8B 5 
512 Parameter 7 for user 0C 8C 5  
513 Parameter 8 for user 0D 8D 5 
514 Parameter 9 for user 0E 8E 5  
515 Parameter 10 for user 0F 8F 5 
522 Output stop frequency 16 96 5  
539 Modbus-RTU communication check time
interval 27 A7 5 *3 *3
542 Communication station number (CC-
Link) 2A AA 5 *3 *3
543 Baud rate selection (CC-Link) 2B AB 5 *3 *3
544 CC-Link extended setting 2C AC 5 *3 *3
549 Protocol selection 31 B1 5 *3 *3
550 NET mode operation command source
selection 32 B2 5 *3 *3
551 PU mode operation command source
selection 33 B3 5 *3 *3
553 PID deviation limit 35 B5 5  
554 PID signal operation selection 36 B6 5 
555 Current average time 37 B7 5  
556 Data output mask time 38 B8 5 
557 Current average value monitor signal
output reference current 39 B9 5  
563 Energization time carrying-over times 3F BF 5× × ×
564 Operating time carrying-over times 40 C0 5 ×× ×
570 Multiple rating setting 46 C6 5× ×
571 Holding time at a start 47 C7 5  
573 4mA input check selection 49 C9 5 
575 Output interruption detection time 4B CB 5  
576 Output interruption detection level 4C CC 5 
577 Output interruption cancel level 4D CD 5  
578 Auxiliary motor operation selection 4E CE 5 
579 Motor connection function selection 4F CF 5  
580 MC switching interlock time 50 D0 5 
581 Start waiting time 51 D1 5  
582 Auxiliary motor connection-time
deceleration time 52 D2 5 
583 Auxiliary motor disconnection-time
acceleration time 53 D3 5  
584 Auxiliary motor 1 starting frequency 54 D4 5 
585 Auxiliary motor 2 starting frequency 55 D5 5  
586 Auxiliary motor 3 starting frequency 56 D6 5 
587 Auxiliary motor 1 stopping frequency 57 D7 5  
588 Auxiliary motor 2 stopping frequency 58 D8 5 
589 Auxiliary motor 3 stopping frequency 59 D9 5  
590 Auxiliary motor start detection time 5A DA 5 
591 Auxiliary motor stop detection time 5B DB 5  
611 Acceleration time at a restart 0B 8B 6 
653 Speed smoothing control 35 B5 6  
654 Speed smoothing cutoff frequency 36 B6 6 
665 Regeneration avoidance frequency gain 41 C1 6  
726 Auto Baudrate/Max Master 1A 9A 7 
727 Max Info Frames 1B 9B 7  
728 Device instance number (Upper 3 digit) 1C 9C 7 
729 Device instance number (Lower 4 digit) 1D 9D 7  
753 Second PID action selection 35 B5 7 
Parameter
Name Instruction Code *1
Parameter
Copy
*2
Parameter
Clear
*2
All Parameter
Clear
*2
Read Write
Extended