12 - 25
12. OPTIONS AND AUXILIARY EQUIPMENT
(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent:
Table 12.2 Wires for option cables
Characteristics of one core
Type Model Length
[m(ft)]
Core size
[mm2]
Number
of Cores Structure
[Wires/mm]
Conductor
resistance[ /mm]
Insulation coating
ODd[mm] (Note 1)
(Note 3)
Finishing
OD [mm]
Wire model
2 to 10
(6.56 to 32.8) 0.08 12
(6 pairs) 7/0.127 222 0.38 5.6 UL20276 AWG#28
6pair (BLACK)
MR-JCCBL M-L 20 30
(65.6 98.4) 0.3 12
(6 pairs) 12/0.18 62 1.2 8.2 UL20276 AWG#22
6pair (BLACK)
2 5
(6.56 16.4) 0.2 12
(6 pairs) 40/0.08 105 0.88 7.2 (Note 2)
A14B2343 6P
MR-JCCBL M-H 10 to 20
(32.8 to 65.6) 0.2 14
(7 pairs) 40/0.08 105 0.88 8.0 (Note 2)
A14B0238 7P
Encoder cable
MR-JC4CBL M-H 30 to 50
(98.4 to 164) 0.2 14
(7 pairs) 40/0.08 105 0.88 8.0 (Note 2)
A14B0238 7P
Communication
cable MR-CPCATCBL3M 3 (9.84) 0.08 6
(3 pairs) 7/0.127 222 0.38 4.6 UL20276 AWG#28
3pair (BLACK)
Bus cable MR-J2HBUS M 0.5 to 5
(1.64 to 16.4) 0.08 20
(10 pairs) 7/0.127 222 0.38 6.1 UL20276 AWG#28
10pair (CREAM)
Battery unit
cable MR-J2MBATCBL M 0.3 1
(0.98 3.28) 0.3 2
(1 pairs) 12/0.18 63 1.5 5.1 MVVS IP 0.3mm2
Note 1. d is as shown below:
d
Conductor Insulation sheath
2. Purchased from Toa Electric Industry
3. Standard OD. Max. OD is about 10% greater.