2 - 1
2. INSTALLATION
2. INSTALLATION
CAUTION
Stacking in excess of the limited num ber of products is not allowed.
Install the equipment on incombustible material. Installing them directly or close to
combustibles will lead to a fire.
Install the equipment in a load-bearing place in accordance with this Instr uction
Manual.
Do not get on or put heavy load on the equipment to prevent injur y.
Use the equipment within the specified environmenta l condition range. (For the
environmental conditions, refer to s ection 1.3.)
Provide an adequate protection to pr event screws, metallic detritus and other
conductive matter or oil and other com bustible matter from entering the servo
amplifier.
Do not block the intake/exhaust ports of the servo amplifier. Otherwise, a fault may
occur.
Do not subject the servo amplifier to drop impact or s hock loads as they are
precision equipment.
Do not install or operate a faulty servo amplifier.
When the product has been stored for an ext ended period of time, consult
Mitsubishi.
When treating the servo amplifier, be c areful about the edged parts such as the
corners of the servo amplifier.
2.1 Environmental conditions
Environment Conditions
[]0 to 55 (non-freezing)
In
operation [] 32 to 131 (non-freezing)
[ ] 20 to 65 (non-freezing)
Ambient
temperature In storage []4 to 149 (non-freezing)
In operation
Ambient
humidity In storage 90%RH or less (non-condensing)
Ambience Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m (3280 ft) above sea level
[m/s2] 5.9 [m/s2] or less
Vibration [ft/s2] 19.4 [ft/s2] or less