
A - 9
CONFORMANCE WITH UL/C-UL STANDARD
(1) Servo amplifiers and servo motors used
Use the servo amplifiers and servo motors which comply w ith the standard model.
Servo amplifier :MR-J2S-10B to MR-J2S-22KB
MR-J2S-10B1 to MR-J2S-40B1
Servo motor :HC-KFS
HC-MFS
HC-SFS
HC-RFS
HC-UFS
HA-LFS
HC-LFS
(2) Installation
Install a cooling fan of 100CFM (2.8m3/min) air flow 4 in (10.16 cm) above the servo amplifier or
provide cooling of at least equivalent capabili ty.
(3) Short circuit rating
This servo amplifier conforms to the circuit whose peak current is limited to 5000A or less. Having
been subjected to the short-circuit te sts of the UL in the alternating-curren t circuit, the servo
amplifier conforms to the above circuit.
(4) Capacitor discharge time
The capacitor discharge time is as listed below. To ensu re safety, do not touch the charging section fo r
10 minutes after power-off.
Servo amplifier Discharge time
[min]
MR-J2S-10B(1) 20B(1) 1
MR-J2S-40B(1) 60B 2
MR-J2S-70B to 350B 3
MR-J2S-500B 700B 5
MR-J2S-11KB 4
MR-J2S-15KB 6
MR-J2S-22KB 8
(5) Options and auxiliary equipment
Use UL/C-UL standard-compliant products.
(6) Attachment of a servo motor
For the flange size of the machine side where the servo motor is installed, refer to “CONFORMANCE
WITH UL/C-UL STANDARD” in the Servo Motor Instructio n Manual.
(7) About wiring protection
For installation in United States, branch circuit protection must be provided, in accordance with the
National Electrical Code and any applicable local codes.
For installation in Canada, branch circuit protection must be provided, in accordance with the Canada
Electrical Code and any applicable provincial codes.