12 - 19
12. OPTIONS AND AUXILIARY EQUIPMENT
(3) Outside dimensions of the power regenerat ion converters
[Unit : mm(in)]
AA
AC
FK
EE BA
BE
D
2- D hole
Rating plate
Front cover
Display
panel
window
Mounting foot (removable)
Mounting foot
movable
Cooling fan
Heat generation area outside mounting dimension
Power
regeneration
converter
AAABBACD EEEK F Approx.
mass [kg(Ib)]
FR-RC-15K 270
(10.6)
200
(7.87)
450
(17.7)
432
(17.0)
195
(7.68)
10
(0.39)
10
(0.39)
8
(0.32)
3.2
(0.13)
87
(3.43)
19
(41.9)
FR-RC-30K 340
(13.4)
270
(10.6)
600
(23.6)
582
(22.9)
195
(7.68)
10
(0.39)
10
(0.39)
8
(0.32)
3.2
(0.13)
90
(3.54)
31
(68.3)
FR-RC-55K 480
(18.9)
410
(16.1)
700
(27.6)
670
(26.4)
250
(9.84)
12
(0.47)
15
(0.59)
15
(0.59)
3.2
(0.13)
135
(5.32)
55
(121)
(4) Mounting hole machining dimensions
When the power regeneration converter is fitted to a totally enclosed type box, mount the heat
generating area of the converter outside the box to provide heat generation measures. At this time, the
mounting hole having the following dimensions is mac hined in the box.
[Unit : mm(in)]
Model A B D AA BA
FR-RC-15K 260
(10.2)
412
(16.2)
10
(0.39)
200
(7.87)
432
(17.0)
FR-RC-30K 330
(13.0)
562
(22.1)
10
(0.39)
270
(10.6)
582
(22.9)
FR-RC-55K 470
(18.5)
642
(25.3)
12
(0.47)
410
(16.1)
670
(26.4)
(AA)
(BA)
b
a
(2- D hole)