14 - 17
14. OPTIONS AND AUXILIARY EQUIPMENT
(3) Outside dimensions of the power r egeneration converters
[Unit : mm(in)]
AA
AC
FK
EE BA
BE
D
2- D hole
Rating plate
Front cover
Display
panel
window
Mounting foot (removable)
Mounting foot
movable
Cooling fan
Heat generation area outside mounting dimension
Power
regeneration
converter
A AA B BA C D E EE K F Approx.
Mass [kg(Ib)]
FR-RC-15K 270
(10.630)
200
(7.874)
450
(17.717)
432
(17.008)
195
(7.677)
10
(0.394)
10
(0.394)
8
(0.315)
3.2
(0.126)
87
(3.425)
19
(41.888)
FR-RC-30K 340
(13.386)
270
(10.630)
600
(23.622)
582
(22.913)
195
(7.677)
10
(0.394)
10
(0.394)
8
(0.315)
3.2
(0.126)
90
(3.543)
31
(68.343)
(4) Mounting hole machining dim ensions
When the power regeneration converter is fitted to a totally enclosed type box, mount the heat
generating area of the converter outside the box to provide heat generation measures. At this time, the
mounting hole having the following dimension s is machined in the box.
[Unit : mm(in)]
Model A B D AA BA
FR-RC-15K 260
(10.236)
412
(16.220)
10
(0.394)
200
(7.874)
432
(17.009)
FR-RC-30K 330
(12.992)
562
(22.126)
10
(0.394)
270
(10.630)
582
(22.913)
Approx. AA
Approx. BA
b
a
(2- D hole)
(Mounting hole)