Hotels generally use dense wall material to reduce audible noise from one room to another.
Concrete is a common material. 20 to 25dB RF loss can be measured through concrete hotel
walls, but actual results may vary.
The worst case would be a client PC sitting approximately midway between two WallPlates on the
same floor. From this location, the client would be within the carrier detect range of multiple
WallPlates.
Rm 205
Anticipated RSSI in Room 205
All WPs at maximum Tx power
Connected to WallPlate H in room 105 on channel 11
Will See AP … At RSSI … On Channel … Co-Channel Notes
A -112dBm 11 No Outside Range
B -60dBm 1 No Different channel
C -112dBm 6 No Outside Range
D -70dBm 1 No Different channel
E -70dBm 6 No Different channel
F -70dBm 11 Yes In range, same ch
G -112dBm 6 No Outside Range
H -60dBm 11 Yes Connected
I -112dBm 1 No Outside Range
D
Ch-1 F
Ch11
E
Ch-6
H
Ch11
Rm 201 Rm 203 Rm 205 Rm 207 Rm 209 Rm 211
Rm 202 Rm 204 Rm 206 Rm 208 Rm 210 Rm 212 Rm 214
Rm 213
I
Ch-1
client
B
Ch-1
-70dBm
-60dBm
-70dBm
-70dBm -112dBm-112dBm
G
Ch-6
A C
Ch11 Ch-6
Motorola, Inc Page 7 of 12