3 - 6 Symbol MiniScan MSXX07 Series Integration Guide
Level TriggerActivating the trigger line enables the laser and begins decode processing. Decode processing continues until a
good decode occurs, the trigger is released, or the Laser On Time expires. The laser is disabled once decode
processing completes. The next decode attempt does not occur until the trigger line is released and then
reactivated.
Level
Pulse TriggerActivating the trigger line enables the laser and begins decode processing. Decode processing continues
regardless of the trigger line until a good decode occurs, or until the Laser On Time expires. The laser is disabled
once decode processing completes. The next decode attempt does not occur until the trigger line is released and
then reactivated.
Pulse
BlinkThe laser blinks at a 25% duty cycle (reduced to 10% after 30 seconds of inactivity), until a bar code is presented.
When a bar code is presented, the laser remains on until either the bar code is decoded or removed, or the session
timeout expires. Once the bar code is decoded, the scanner does not decode it again until the bar code is
removed.
Blink
NOTE Only the Symbol MS1207FZY and MS1207WA support this option.