Figure 6-2. Format of 16-Bit Timer Mode Control Register 20
Symbol <7> <6> 5 4 3 2 1 <0> Address After reset R/W
TMC20 TOD20 TOF20 CPT201 CPT200 TOC20 TCL201 TCL200 TOE20 FF48H 00H R/WNote 1
TOD20 Timer output data
0 Timer output is “0”
1 Timer output is “1”
TOF20 Set overflow flag
0 Reset and clear by software
1 Set by overflow of 16-bit timer
CPT201 CPT200 Selection of capture edge
0 0 Capture operation disabled
0 1 Rising edge of CPT20 pin
1 0 Falling edge of CPT20 pin
1 1 Both edges of CPT20 pin
TOC20 Timer output data inversion control
0 Inversion disabled
1 Inversion enabled
TCL201 TCL200 Selection of count clock for 16-bit timer counter 20
0 0 Timer 61 interrupt signal
0 1 fX (5.0 MHz)Notes 2, 3
1 0
fX/22 (1.25 MHz)Note 4
1 1
fX/25 (156.25 kHz)Note 4
TOE20 Output control for 16-bit timer counter 20
0 Output disabled (port mode)
1 Output enabled
Notes 1. Bit 7 is read-only.
2. If fX is selected for the count clock, the signal cannot be used as a capture signal.
3. In a read operation, set the CPU clock as the high-speed main clock (PCC1 = 0, CSS = 0).
4. In a read operation, set the CPU clock as the main clock (CSS = 0).
Remarks 1. fX: Main system clock oscillation frequency
2. The parenthesized values apply to operational fX = 5.0 MHz.