CHAPTER 16 ELECTRICAL SPECIFICATIONS
User’s Manual U12978EJ3V0UD
214
AC Characteristics
(1) Basic operations (TA =
40 to +85°
°°
°C, VDD = 4.0 to 5.5 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
When PCC = 00H (fX = 6.0 MHz) 0.333 0.333 0.333
µ
s
Cycle time (minimum
instruction execution time)
TCY
When PCC = 02H (fX = 6.0 MHz) 1.333 1.333 1.333
µ
s
TI01 input frequency fTI 04.0MHz
TI01 input high-/low-level
width
tTIH, tTIL 0.1
µ
s
Interrupt input high-/low-level
width
tINTH, tINTL INTP0 10
µ
s
RESET input low-level width tRSL 10
µ
s
(2) Serial interface
(a) USB function (TA = 0 to +70°
°°
°C, VDD = 4.0 to 5.5 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
CL = 50 pFNote 75 nsUSBDM and USBDP rise time tR
CL = 350 pFNote 300 ns
CL = 50 pFNote 75 nsUSBDM and USBDP fall time tF
CL = 350 pFNote 300 ns
tR and tF matching tRFM tR/tF80 120 %
Differential output signal
cross-over point
VCRS 1.3 2.0 V
Data transfer rate tDRATE When the mi crocontroller operates at the
system clock (fX) of 6.0 MHz
1.5 1.5 1.5 Mbps
tUDJ1 Upon transferring the next bit 95 095nsTransmission differential
signal jitter tUDJ2 Upon transferring the bit following the next bit 150 0 150 ns
Transmission EOP width tEOPT1 1.25 1.33 1.50
µ
s
tEOPR1 EOP width to be eliminated 300
µ
s
Reception EOP width
tEOPR2 EOP width to be detected 675
µ
s
tURES1 USB reset width to be eliminated 2.5
µ
s
Reception USB reset width
tURES2 USB reset width to be detected 5.5
µ
s
Note CL is the capacitance of the USBDM and USBDP output lines.