CHAPTER 6 8-BIT TIMER/EVENT COUNTERS 00 AND 01
Users Manual U12978EJ3V0UD 89
Figure 6-9. Timing of Square-Wave Output
Clear Clear
Interrupt acknowledged Interrupt acknowledged
Count start
Count clock
TM01 count value
CR01
TCE01
INTTM01
TO01Note
N0100N0100N00 01
NN NN
Note The initial value of TO01 when output is enabled (TOE01 = 1) becomes low level.