91
iii. Press the DELAY button again and repeat the previous step to add another delay. (For example, you can
have two consecutive one-second delays.)
or
Continue with your editing.
Step 7 - Repeat steps 4 – 6 until you have re-entered all the steps for the Master Key Sequence you are editing.
Step 8 - Press the PROGRAM key to edit the Master Key Sequence for a different Master Key.
The TRIGGER LED turns on RED, and the PAGE LED continues to blink RED.
Step 9 - Repeat steps 3 through 8 until all Master Key Sequences have been edited.
Step 10 - Press NEXT to edit Zone and System ON/OFF sequences. The (INPUT)/ZONE-SYS SEQ LED turns
on GREEN, the TRIGGER LED turns on RED, and the PAGE LED blinks RED. The LED for Zone 1 blinks
GREEN, indicating that Zone 1 is selected by default.
or
Step 10 - Press PROGRAM to save and exit programming.
EDIT PROGRAMMING FOR ZONE AND SYSTEM ON/OFF SEQUENCE
Step 1 - Press and hold the PROGRAM button
Step 2 - Press the NEXT button four times.
The (INPUT)/ZONE-SYS SEQ LED turns on GREEN, the TRIGGER LED turns on RED, and the PAGE LED
blinks RED. The LED for Zone 1 blinks GREEN, indicating that Zone 1 is selected by default.
Step 3 - To edit a sequence for a zone other than Zone 1, press the Zone Select button until the LED for the
desired Zone blinks GREEN. All other LEDs should be off.
or
To edit a system sequence, press the Zone Select button six times until all LEDs are blinking.
Step 4 - Press the ZONE ON button to edit the desired Zone/System On Sequence.
The INPUT 1 LED turns on.
or
Press the ZONE OFF button to edit the desired Zone/System OFF.
The INPUT 4 LED turns on.
The selected zone's LED stops blinking and turns on solid GREEN. The TRIGGER LED turns off and the
PAGE LED blinks RED.
Step 5 - Press the Master Key that identifies the Master Key Page where the IR command is stored for the
first step in the Zone/System Sequence you are editing.
or
PROGRAM-EDITING STEPS