490 NT7D16 Data Access card
I/O cable RS-232-C
Pair Pin Pair
color Unit no. Signal Pinno. RS-422
Signal Patch pair or
octopus
22T 47 V-O DTR5 20 SDA5
22R 22 O-V GND5 7SDB5 Connector
23T 48 V-G DCD5 83
23R 23 G-V DSR5 6
24T 49 V-BR RI5 22
24R 24 BR-V CTS5 5
Note: Units 4 and 5 are available when the DAC is installed in a fully wired 24-pair slot.
Configuring the Data Access card

LD 11 must be configured to accept the DAC.The commands listed here

must be answered. LD 20 prints out card information when requested. For a

complete list of the service change prompts and responses, see Software

Input/Output Reference — Administration (NN43001-611).

DAC administration (LD 11)

Responding R232 or R422 to the TYPE prompt in LD11 begins the prompt

sequence for the DACconfiguration. Responses to the following prompts

are required. The defaults are bracketed, and may be issued by Carriage

Return (<CR>).

LD 11 - Configure Data Access card.
Prompt Response Description
REQ: NEW CHG MOV
COPY Add, change, move or copy the unit
TYPE: R232
R422 RS-232-C unit
RS-422 unit
TN l s c u DAC data TN.The loop (LL) must be a superloop.
RNPG <CR> Ringing number pickup group (default to zero)
CLS Class of Service allowed for the DAC.
DTA
ADD Data Allowed
Digit Display Allowed
TOV (0) - 3 Timeout value, where:
0 = no timeout
1 = 15 minutes
2 = 30 minutes
3 = 60 minutes
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright© 2003-2008, Nor tel Networks
.