Cell Site Layouts 3-27
Transmit cabling
In the transmit path, the output of each Transmit Receive Unit (TRU) is connected to the input of each corresponding power amplifier (PA) on the Dual Power Amplifier (DPA) module.
For a 60° STSR cell site with two RF Frames, each TRU/DPA Shelf and its associated ATC and duplexer serve for one of the six sectors as listed below:
•Sector X RF Frame
•Sector Y RF Frame
•Sector Z RF Frame
•Sector U RF Frame
•Sector V RF Frame
•Sector W RF Frame
The output of each power amplifier (PA) is input to an
For a 60° STSR cell site with four RF Frames, the assignment of the equipment for each sector is as listed below:
•Sector X RF Frame 1
TRU/DPA Shelf 2, ATC 2 and Duplexer 2
•Sector Y RF Frame 2
TRU/DPA Shelf 2, ATC 2 and Duplexer 2
•Sector Z RF Frame 1
RF Frame 2
•Sector U RF Frame 3
TRU/DPA Shelf 2, ATC 2 and Duplexer 2
•Sector V RF Frame 4
TRU/DPA Shelf 2, ATC 2 and Duplexer 2
•Sector W RF Frame 3
By adding one more RF Frame to this configuration, three of the six sectors can be expanded to provide up to 24 channels (including the CCH and LCR). With this additional RF Frame, the equipment and cabling may need to be reassigned and rearranged. Table