pg. 10, OMB-DBK Basics 02-19-02 Daq Systems
DBK Power Requirement Worktable—Demand
DBK Voltage Reference Calculation
Options +15 VDC -15 VDC +5 VDC Quantity × mW = Sub Total
DBK1 0 0 0 0
DBK2 18 mA 18 mA 5 mA 565
DBK4 95 mA 80 mA 25 mA 2750
DBK5 2 mA 2 mA 15 mA 135
DBK7 14 mA 8 mA 18 mA 420
DBK8 15 mA 15 mA <1 mA 455
DBK9 21 mA 16 mA <1 mA 560
DBK11A 0 0 0 0
DBK12 15 mA 15 mA <1 mA 455
DBK13 15 mA 15 mA <1 mA 455
DBK15 16 mA 16 mA <1 mA 485
DBK16 37 mA 32 mA <1 mA 1040
DBK17 30 mA 30 mA <1 mA 905
DBK18 36 mA 36 mA <1 mA 1085
DBK19 6 mA 7 mA <1 mA 200
DBK20 0 0 <10 mA 50
DBK21 0 0 <10 mA 50
DBK23*** 0 0 <2 mA 10
DBK24*** 0 0 <2 mA 10
DBK25 0 0 <2 mA 10
DBK40 0 0 0 0
DBK41 0 0 0 0
DBK42 <1 mA <1 mA <1 mA 35
DBK43A*** <1 mA <1 mA <1 mA 35
DBK44 <1 mA <1 mA 60 mA (Note 1) 330
DBK45 52 mA 52 mA <1 mA 1565
DBK50*** <1 mA <1 mA <1 mA 35
DBK51*** <1 mA <1 mA <1 mA 35
DBK52 6 mA 7 mA <1 mA 200
DBK53 15 mA 15 mA <1 mA 455
DBK54 15 mA 15 mA <1 mA 455
DBK80 25 mA 25 mA <1 mA 755
DBK81 35 mA 35 mA <2 mA 1060
DBK82 60 mA 60 mA <2 mA 1810
DBK83 60 mA 60 mA <2 mA 1810
DBK84 60 mA 60 mA <2 mA 1810
Total Power Requirement in mW
Note 1: DBK44’s 60 mA value is based on 30 mA for each of two 5B modules. This value will be higher if using
5B module 5B38 (200 mA for each 5B38), or if using 5B39 (170 mA for each 5B39). Refer to the DBK44
document module for more information.
Note 2: DBK2 and DBK5 are not used with LogBook.
*** Three asterisks indicate that the DBK is a module with internal power supply; powered separately.