Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner
MSI/Plessey Settings
ZZ Start/End
Program
Menu [[
4A Do not
check CD 5B
4B Check 1 CD =
Mod 10 5C
%
4C Check 2 CD's
= Mod 10
/Mod 10 %D
4D Check 2 CD's
= Mod 10
/Mod 11 5E
4E Transmit CD1 5F
%
4F Transmit CD1
and CD2 5G
4G Do not
transmit CD 5H
4R Check 2 CD's
= Mod 11
/Mod 10 5S
MSI Plessey is a variable length symbology with one or two optional check digit calculations CD1 and CD2 and non printable
start/stop characters. Supported characters include numeric digits 0 through 9.
The checksum is calculated as the sum modulo 10 or 11 of the data characters. The checksum CD2 is calculated as the sum
modulo 10 or 11 of the data characters and CD1.
String format:
data (1 to
13 digits) CD1 CD2
Options for MSI/Plessey:
* Disable check digit check.
* Selection of the check digit calculation.
* Selection of the number of check digits to be transmitted.
Check digit - If the check digit calculation is required, then the appropriate calculation method must be selected.
Do not transmit CD - The character positions CD1 and CD2 are not transmitted.
Transmit CD1 - The character position CD2 is not transmitted.
Transmit CD1 and CD2 - All characters in the label are transmitted.
Page 30