Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner
Read Mode Settings
ZZ Start/End
Program
Menu [[
S0 Single
read T1
S1 Multiple
read T2
%
S2 Continuous
read T3
XA Add-on
wait mode
disabled YB
XB Add-on
wait mode
0.25 sec. TC
XC Add-on
wait mode
0.50 sec. YD
%
XD Add-on
wait mode
0.70 sec. YE
Single Read - When a bar code has been decoded, the reader will be turned OFF. The reader must be triggered again to read
another label. This option and "Disable trigger" cannot be programmed at the same time.
Multiple Read - When a bar code has been decoded, the reader will stay ON for a time as set by "read time settings" or
indefinitely if the trigger switch has been disabled. The same label can only be decoded again after the label has not been detected
for a number of scans.
Continuous Read - The reader will produce as much data as it can decode regardless whether it is the same or not. This mode is
mainly used for demonstration and diagnosis.
Add-on Wait Mode - Used if UPC/EAN with add-on is enabled. The reader searches within the selected time for a valid add-on
code. If a valid add-on code is found, the reader transmits the data immediately. If nothing is found behind the code, the scanner
will transmit the data without add-on. If something is found behind the code, the reader ignored the code in case it is not a valid
add-on.
Page 53