Troubleshooting Procedures Troubleshooting
11-6 Centillion 1200N ATM Switch User Manual
NTP 297-8103-903
Alarm Error
Numbers Alarm Error Number (Environment)

Alarm Error Number (Switch/CPU Card Error)

Alarm No. Nature of Error
- POWER alarm
- FAN alarm
000001 Abnormal rise in environmental temperature
Alarm Type, Number Part Nature of Error
Diagnosis NG 070002 MEMORY Memory diagnosis NG
Diagnosis NG 050005 SAR SAR register NG
Path Alarm 020002 SC Cell alignment signal error
Path Alarm 020003 SC BMT parity error
Path Alarm 030001 BF Regression enable match error
Path Alarm 030002 BF Regression clear match error
Path Alarm 030003 BF BF0 parity error
Path Alarm 030103 BF BF1 parity error
Path Alarm 040001 ES ES0 Up side sync error
Path Alarm 040002 ES ES0 Down side sync error
Path Alarm 040004 ES ES0 port A FIFO overflow
Path Alarm 040006 ES ES0 port B FIFO overflow
Path Alarm 040101 ES ES1 Up side sync error
Path Alarm 040102 ES ES1 Down side sync error
Path Alarm 040104 ES ES1 port A FIFO overflow
Path Alarm 040106 ES ES1 port B FIFO overflow
Path Alarm 060004 D/I Header conversion table parity error
Diagnosis NG 040007 ES ES0 diagnosis NG
Diagnosis NG 040107 ES ES1 diagnosis NG
Diagnosis NG 020004 SC SC diagnosis NG
Diagnosis NG 030004 BF BF diagnosis NG
Diagnosis NG 060010 D/I DI diagnosis NG