Setup menus

USER menu

<AUDIO> (continued)

 

Item

 

Setting

 

 

 

 

 

 

 

 

 

Description

No.

Superimposed

No.

 

Superimposed

display

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

736

CUE SLOW

0000

 

 

STEP

 

For selecting the tape travel status (cue track playback status)

 

 

0001

 

 

LINEAR

during slow-motion playback.

 

 

 

 

 

 

 

 

0: The output picture takes precedence, and the tape travels

 

 

 

 

 

 

 

 

at the STEP speed.

 

 

 

 

 

 

 

 

1: The cue track playback takes precedence and the tape

 

 

 

 

 

 

 

 

travels at the linear playback speed.

 

 

 

 

 

 

 

 

<Notes>

 

 

 

 

 

 

 

 

When “1” (LINEAR) has been selected:

 

 

 

 

 

 

 

 

• Set the TC/CTL switch to the TC position because the CTL

 

 

 

 

 

 

 

 

counter may not function properly.

 

 

 

 

 

 

 

 

• The picture may not appear as clearly as in the STEP mode.

 

 

 

 

 

 

 

 

737

CH1 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH1 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

738

CH2 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH2 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

739

CH3 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH3 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

740

CH4 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH4 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

741

CH5 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH5 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

742

CH6 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH6 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

743

CH7 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH7 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

744

CH8 CUE

0000

 

 

OFF

This selects whether the CUE signal is to be output to the

 

SEL

0001

 

 

ON

 

main line of CH8 in the search mode.

 

 

 

 

 

 

 

 

0: The CUE signal is not output.

 

 

 

 

 

 

 

 

1: The CUE signal is output.

 

 

 

 

 

 

 

 

 

The underline on the setting item denotes the initial setting.

– 74 –