FUNCTION 3/5 ScreenThis page performs the adjustment function 3 settings.
Item
HUMID OPE
26P CONTROL
REC START
TC MODE
UB MODE
PAUSE TIMER
BATTERY SEL
TCG VF DISP
TCG SET HOLD
Variable
range
ON
OFF
OFF
BOTH
ON
ALL
NORMAL
DF
NDF
USER
REAL
EXT
10
20
30
NiCd-12
NiCd-13
NiCd-14
DIGITAL
ON
OFF
ON
OFF
VF
display
ENG
ENG
ENG
ENG
ENG
ENG
ENG
ENG
ENG
Remarks
VTR operation selection when
condensation occurs.
ON: Operation continues normally.
OFF: All operations prohibited except
for POWER switch and EJECT button.
26P remote control selection
OFF: Unit only (26P control does not
function.)
BOTH: Unit and 26P remote control
(TALLY LED indicates unit REC
status.)
ON: 26P remote control only (TALLY
LED indicates 26P VTR REC status.)
REC acceptance selection for VTR
START/STOP
ALL: REC accepted regardless of
VTR mode.
NORMAL: REC accepted only during
STOP (POWER SAVE) mode and
REC PAUSE mode.
Time code DF/NDF switching
DF: Drop frame mode
NDF: Non-drop frame mode
LTC UB usage method selection
USER: User setting (fixed value)
REAL: Real-time operation according
to the TIME DATE time
EXT: When there is external TC input,
the UBG value is slave locked. (When
there is no external input, the user
setting is used.)
Selection for the recording/pause hold
time.
10: 10 minutes
20: 20 minutes
30: 30 minutes
Battery type selectionF
NiCd-12: 12 V Nicad battery
NiCd-13: 13 V Nicad battery
NiCd-14: 14 V Nicad battery
DIGITAL: Digital battery
Viewfinder time code display ON/OFF
ON: Time code is displayed.
OFF: Time code is not displayed.
TCG operation selection when TCG
SET>power OFF>power ON>REC
is selected.
ON: The fact that TCG SET has been
selected is stored in the memory when
the power is switched off, and
regeneration is not performed.
OFF: Regeneration is performed
without storing the fact that TCG SET
has been selected in the memory
when the power is switched off.
|Notes{
¡Set SW201 on the CAM ENC
board to ON when 26P CON-
TROL is to be used.
¡Change the time on the TIME/
DATE menu screen when the
REAL setting is used for UB
MODE.
FEven if the BATTERY SEL is selected
to NiCd-12, 13 or 14, the camera auto-
matically senses whether or not an An-
ton Bauer’s Intelligent Battery is fitted.
In the case of an intelligent battery, a
numerical indication (percentage) of
power available is displayed in the
viewfinder. If the camera is usually used
with an intelligent battery, BATTERY
SEL should be set to DIGITAL.
-
FUNCT I
O
N3/
5
-
¢
HU
M
ID
O
HD
O
PE :
O
F
F
26P C
O
NTR
O
L:
O
F
F
REC STAR
T
:N
O
R
M
AL
TC
M
M
O
DE :DF
UB
M
O
DE :USER
PA
S
E
T
T
:30UEIR
BATTERY SE
SE
L
L
:NiCd
-
12
TC
G
TC
G
VF DI SP :
O
F
:F
O
FF