13.4.2.3. Removal of Control Plate Casing

1.Remove the Cabinet Top Plate and Cabinet Front Plate according to the item 13.5.2.1.

2.Remove the Control Cover (2- / 3-way valve Covers and Terminal Cover) according to the item 13.5.2.2.

3.Remove the Control Plate Casing by releasing hooks (four: two each on the right and left).

CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE

6.Disconnect the interconnect cables and the Earth Wire (one screw).

••Remove the screws (two) fixing the Terminal part and the Cabinet Side Plate (right).

Fig. 5

4. Remove the screw (one) fixing the Control Plate Casing.

Fig. 6

5.Disconnect a variety of connectors and Terminals.

Wiring cables from lower side

••Compressor cables (red, blue and yellow)

...... Disconnect the connector (white).

••CN-HOT (white) ...... Electromagnetic Coil (4-way valve) Cable: Yellow

••Terminals connecting Reactor (two) Cable: Gray

••CN-TANK (white) ...... Compressor Temp. Sensor

Wiring cables from left side

••CN-FM1 ...... Outdoor Fan Motor

Wiring cables from right side

••CN-STM (white) ...... Electromagnetic Coil (Expansion Valve)

••CN-TH (white) ...... Outdoor Air Temp. / Pipe Temp. Sensor

Fig. 7

7.Remove the Control Plate Casing from the main unit by holding it up.

Fig. 8

71