NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET

HHR300CH Cylindrical C size (HR 26/50) for backup use
Dimensions (with Tube)
(mm)

25.8 +- 01.0

(+)

50.0 +- 01.5

( )

Specifications

 

 

 

 

 

mm

 

 

inch

 

 

 

 

 

 

 

 

 

 

Diameter

 

 

25.8+0/-1.0

 

1.02+0/-0.04

 

 

Height

 

 

50.0+0/-1.5

 

1.97+0/-0.06

 

 

Approximate

 

Grams

 

 

Ounces

 

 

Weight

 

 

80

 

2.82

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Voltage

 

1.2V

 

Discharge

 

Average2
3300 mAh

 

Capacity1

 

Rated (Min.)
3100 mAh

 

 

 

 

 

 

 

 

 

 

Approx. Internal impedance

 

5m

 

at 1000Hz at charged state.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard
300mA (0.1It) x 16hrs.

 

Charge

 

Rapid3
1500mA (1It) x 2.4 hrs.4

 

 

 

 

Low Rate

155mA x 32 hrs.

 

 

 

 

100mA x 48 hrs.

 

 

 

 

 

 

 

 

 

 

Standard

˚C

 

 

˚F

 

Ambient Temperature

Charge

 

0˚C to 45˚C

 

 

32˚F to 113˚F

 

 

 

 

 

 

 

 

Rapid
10˚C to 40˚C

 

 

32˚F to 104˚F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Rate

-10˚C to 45˚C

 

 

14˚F to 149˚F

 

 

Discharge
-10˚C to 65˚C

 

 

14˚F to 113˚F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< 1 year
-20˚C to 35˚C

 

 

-4˚F to 95˚F

 

 

Storage

 

< 3 months

-20˚C to 35˚C

 

 

-4˚F to 95˚F

 

 

 

 

< 1 month
-20˚C to 55˚C

 

 

-4˚F to 131˚F

 

1After charging at 0.1It for 16 hours, discharging at 0.2It.
2For reference only.
3Need specially designed control systemControl System:dT/dt cut-off; 1 to 2°C/min-UV cut-off; -UV per cell = 5 to 10 mV T-control; T=65°CRapid charger timer; 2.4h (at 1.25a) Trickle timer; within 2h4With control system

Battery performance and cycle life are strongly affected by how they are used. In order to maximize battery safety, please consult Panasonic when determining charge / discharge specs, warning label contents and unit design.

Typical Charge Characteristics

 

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charge: 300mA(0.1 It) x 16hrs.

 

 

 

 

 

 

 

 

 

 

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(V)

1.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

1.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

 

 

 

10˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.8

 

 

 

 

 

 

 

 

 

 

60˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

2

4

6

8

10

20

30

40

50

60

Charge Time (hours)
Typical Discharge Characteristics

 

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110

 

 

 

 

 

 

 

 

 

 

 

(%)

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

Ratio

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

 

 

 

 

 

 

 

 

70

 

Charge Temperature: -10 to 60˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

Charge: 300mA (0.1 It) x 16 hrs.

 

 

 

 

 

 

50

 

Discharge: 600mA (0.2 It)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

Cut-off Voltage: 1.0V

 

 

 

 

 

 

 

 

 

Discharge Temperature: 25˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20

-10

0

10

20

30

40

50

60

70

Temperature (°C)

1.8

Charge: 300mA(0.1It) x 16 hrs., 25°C

Discharge: 10A, 20A, 25°C

1.6

(V)

1.4

 

 

 

 

 

 

 

 

 

 

Voltage

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20A

 

 

0.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

10

15

20

25

30

 

0

Discharge Time (minutes)

Note: [It] was previously expressed as [C]. [It] is an IEC standard expression for the amount of charge or discharge current and is expressed as: It(A) = Cn (Ah)/1h.

[It] is the reference test current in ampres[Cn] is the rated capacity of the cell or battery in Ampere-hours.n = the time base [hours] for which the rated capacity is declared
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005

This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.