Routine care

Removing the handset cradle

To save space or to use the unit mainly for faxes, you may remove the handset cradle.

1

Set the handset switch to “NO HANDSET”

 

(see page 65).

 

2

Pull the hooks to the right in the order as shown,

Hooks

 

while lifting up the handset cradle.

 

3

Disconnect and connect the power cord.

 

 

 

2

Caution:

1

If the handset and handset cradle have been removed

 

 

when you connect the power cord, an alarm will

 

 

sound and the following message will be displayed.

 

CHECK CRADLE

Set the handset switch to “NO HANDSET” (see page 65).

Cleaning the inside of the unit

If misfeeding occurs frequently or dirty patterns or black bands appear on a copied or transmitted document, clean the document feeder rollers, sub roller, rubber flap, white plate and glass.

1

cord.Disconnect the power cord and the telephone line

2

Open the front cover by pressing the front cover

open button.

3

Clean the document feeder rollers and sub roller

with a cloth moistened with isopropyl rubbing

 

alcohol, and let dry thoroughly.

4

Clean the rubber flap with a cotton swab

moistened with isopropyl rubbing alcohol, and let

 

dry thoroughly.

5

Clean the white plate and glass with a soft dry

cloth.

6

Close the front cover by gently pressing down on

both corners of the cover.

7

Connect the power cord and the telephone line

cord.

Caution:

Do not use paper products (such as paper towels or tissues) to clean the inside of the unit.

White plate

 

Rubber flap

 

 

Document

Sub roller

feeder rollers

 

Glass

Front cover open button

Troubleshooting Care Routine and

75