Schottky Barrier Diodes (SBD)

1
Publication date: April 2004 SKH00038BED
MA2Z785 (MA785)

Silicon epitaxial planar type

For super high speed switching
For small current rectification
Features
High-density mounting is possible
Forward current (Average) IF(AV) = 100 mA rectification is
possible
Optimum for high frequency rectification because of its short
reverse recovery time trr
Low forward voltage VF and good rectification efficiency
Reverse voltage VR = 50 V is guaranteed
Absolute Maximum Ratings Ta = 25°C
Marking Symbol: 2E
Parameter Symbol Rating UnitReverse voltage VR50 VRepetitive peak reverse voltage VRRM 50 VPeak forward current IFM 300 mAForward current (Average) IF(AV) 100 mANon-repetitive peak forward IFSM 1A
surge current *
Junction temperature Tj125 °CStorage temperature Tstg 55 to +125 °CParameter Symbol Conditions Min Typ Max UnitForward voltage VFIF = 100 mA 0.55 VReverse current IRVR = 50 V 30 µATerminal capacitance CtVR = 0 V, f = 1 MHz 25 pFReverse recovery time *trr IF = IR = 100 mA 3.0 nsIrr = 0.1 IR, RL = 100
Electrical Characteristics Ta = 25°C ± 3°C
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 100 mA
I
R
= 100 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 0.1 I
R
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1: Anode
2: Cathode
EIAJ: SC-76 SMini2-F1 Package
1.25
±0.1
0.7
±0.1
2.5
±0.2
1.7
±0.1
0.4
±0.1
0 to 0.1
(0.15)
0.16
0.5
±0.1
1
2
+0.1
–0.06
0.35
±0.1
0 to 0.1
Note) *: The peak-to-peak value in one cycle of 50 Hz sine wave (non-repetitive)Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human bodyand the leakage of current from the operating equipment.3.Absolute frequency of input and output is 200 MHz. 4. *: trr measurement circuitNote) The part number in the parenthesis shows conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).