Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00074CED
EIAJ: SC-59
Mini3-G1 Package
Parameter Symbol Rating Unit
Reverse voltage VR30 V
Maximum peak reverse voltage
VRM 30 V
Peak forward current
Single IFM 150 mA
Double 110
Forward current Single IF30 mA
Double 20
Junction temperature Tj125 °C
Storage temperature Tstg 55 to +125 °C
MA3X704D (MA704WA), MA3X704E (MA704WK)
Silicon epitaxial planar type
For switching
For wave detection
Features
Two MA3X704A (MA704A) is contained in one package
Low forward voltage VF and good wave detection efficiency η
Small temperature coefficient of forward characteristic
Small reverse current IR
Absolute Maximum Ratings Ta = 25°C
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage VF1 IF = 1 mA 0.4 V
VF2 IF = 30 mA 1.0
Reverse current IRVR = 30 V 1 µA
Terminal capacitance CtVR = 1 V, f = 1 MHz 1.5 pF
Reverse recovery time *trr IF = IR = 10 mA 1.0 ns
Irr = 1 mA, RL = 100
Detection efficiency ηVIN = 3 V(peak) , f = 30 MHz 65 %
RL = 3.9 k, CL = 10 pF
Electrical Characteristics Ta = 25°C ± 3°C
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 10 mA
I
R
= 10 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 1 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
Marking Symbol
MA3X704D: M2P MA3X704E: M2R
Internal Connection
12
3
12
3
DE
MA3X704D MA3X704E
1 Cathode 1 Anode 1
2 Cathode 2 Anode 2
3 Anode Cathode
Unit: mm
0.40+0.10
–0.05
(0.65) 1.50+0.25
–0.05
2.8+0.2
–0.3
2
1
3
(0.95) (0.95)
1.9±0.1
2.90+0.20
–0.05
0.16+0.10
–0.06
0.4±0.2
10˚
0 to 0.1 1.1+0.2
–0.1
1.1+0.3
–0.1
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3.Absolute frequency of input and output is 2 GHz.
4.*: trr measurement circuit
Note) The part numbers in the parenthesis show conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).