Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00103BED
MA4X713 (MA713)
Silicon epitaxial planar type
For switching
For wave detection
Features
Two isolated elements are contained in one package, allowing
high-density mounting
Two MA3X704A (MA704A) is contained in one package (of a
type in the same direction)
Forward voltage VF , optimum for low voltage rectification
Optimum for high frequency rectification because of its short
reverse recovery time trr
Absolute Maximum Ratings Ta = 25°C
Parameter Symbol Rating Unit
Reverse voltage VR30 V
Maximum peak reverse voltage
VRM 30 V
Peak forward Single IFM 150 mA
current Double *110
Forward current Single IF30 mA
Double *20
Junction temperature Tj125 °C
Storage temperature Tstg 55 to +125 °C
Internal Connection
Marking Symbol: M1N
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage VF1 IF = 1 mA 0.4 V
VF2 IF = 30 mA 1.0
Reverse current IRVR = 30 V 1 µA
Terminal capacitance CtVR = 1 V, f = 1 MHz 1.5 pF
Reverse recovery time *trr IF = IR = 10 mA 1.0 ns
Irr = 1 mA, RL = 100
Detection efficiency ηVin = 3 V(peak) , f = 30 MHz 65 %
RL = 3.9 k, CL = 10 pF
Electrical Characteristics Ta = 25°C ± 3°C
4
1
3
2
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
Rs = 50
Wave Form Analyzer
(SAS-8130)
Ri = 50
tp = 2 µs
tr = 0.35 ns
δ = 0.05
IF = 10 mA
IR = 10 mA
RL = 100
10%
Input Pulse Output Pulse
Irr = 1 mA
trtp
trr
VR
IF
t
t
A
Unit: mm
1: Cathode 1
2: Cathode 2
3: Anode 2
4: Anode 1
EIAJ: SC-61 Mini4-G1 Package
2.90
+0.02
–0.05
0.16
+0.1
–0.06
0.4
±0.2
10˚
0.60
+0.10
–0.05
1.1
+0.2
–0.1
1.1
+0.3
–0.1
1.50
+0.25
–0.05
2.8
+0.2
–0.3
1.9
±0.2
(0.65)
(0.2)
(0.95)(0.95)
0 to 0.1
34
21
0.5R
Note) *:Value of each diode in double diodes used.
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3.Absolute frequency of input and output is 2 GHz. 4. *: trr measurement circuit
Note) The part number in the parenthesis shows conventional part number.