TO CHECK BRUSHES:
When brushes are worn to the level
of the base support bar,replace the
agitator.
TO REPLACE BRUSH AGITATOR
UNIT
Remove POWER NOZZLE cover,
belt and agitator assembly. (See
“REMOVING BELT”).
Remove agitator supports,
washers,screws, end brush, brush
sprocket,and brush sprocket
flange from ends of agitator
assembly.
Replace agitator assembly.
Reassemble agitator assembly.
To line up screw holes in dowel,
sprocket and end brush,be sure the
brush portion of end brush lines up
with brushes on brush dowel.
Replace belt,agitator assembly and
POWER NOZZLE cover screws.
(See “REPLACING BELT”).
BaseSupport Bars
Barresde support
dela base
Electrical Shock Or Personal Injury
Hazard
Disconnect electrical supply before
servicing or cleaning the unit.
Failure to do so could result in elec-
trical shock or personal injury from
cleaner suddenly starting.
WARNING

Brush Servicing

Overload Tools-
POWER Protector Headlight On-Board Cord Length Cord Reel
120V.AC (60Hz) Yes Yes Yes 20 Ft.(6.1 m) Yes
12.0 A
Protector Almacen-
contra Extensión amiento
Voltaje subrecargas Luz Herramientas de cordón del cordón
120V.AC (60Hz) Si Si Si 6,1 m (20 pi) Si
12,0 A
Protecteur Dispositif Longueur Rappel
Alimentation de surcharge d’éclairage Accessoires du cordon du cordon
120 V c.a.(60 Hz) Oui Oui Oui 6,1 m (20 pi) Oui
12,0 A