- 21 -
Preparations and Adjustments
For 3-phase 200VACFor 1-phase 100V/200V

<Note>

In case that alarm occurs, construct the circuits so that the main power is switched off.

172167-1 5557-10R-210
5557-06R-210
172159-1
1
2
ALM
V
DC
9
3
6
4
1
3
5
6
8
10
ALM
L2
L3
PP
P
MC L
MC
NFB
MC
ON OFF
N
N
B
U
V
E
W
L1
COM –
13
12~24V
3
4
tyco Electronics AMPtyco Electronics AMP
Red
White or yellow
Green/yellow
Black
Noise filterMotor
3-phase
200V
1
2
ALM
V
DC
9ALM
L2
L3
PP
P
MC L
MC
NFB
MC
ON OFF
N
N
B
U
V
W
E
L1
COM –
13
12~24V
3
4
172167-1 172159-1 5557-10R-210
5557-06R-2103
6
4
1
3
5
6
10
Noise filter
tyco Electronics AMP tyco Electronics AMP
Red
White or yellow
Green/yellow
Black
Motor

Single-phase 100V or

Single-phase 200V