ENGLISH
37
Automatic adjustment (AUTO SETUP)
Automatic adjustment function adjust the resolution, clock phase and image position automatically when dots-
structured analogue RGB signals such as computer signal are supplied. (Automatic adjustment is not available if
signals or moving images other than analogue RGB signals are supplied.)
It is recommended to supply images with a bright white frame at the outermost periphery containing characters etc.
that are clear in white and black contrast when the system is in automatic adjustment mode. Avoid supplying
images that involve halftones or gradation such as photographs and computer graphics.
Note • A message “COMPLETE” appears if adjustment is ended normally.
• “CLOCK PHASE” may have been shifted even when the adjustment ended normally.
In this case, manually adjust the “CLOCK PHASE”.
• If an image with blurred edges or a dark image is supplied, a message “INCOMPLETE” appears,
indicating the automatic adjustment was unsuccessful.
In this case, manually adjust the items of “INPUT RESOLUTION”, “CLOCK PHASE” and “SHIFT”.
• For specific signals and long-sideways (or landscape) signals such as 16:9, adjustment should be
made according to “AUTO SETUP” in the option menu.
• Automatic adjustment may not be available depending on the machine type of the personal computer.
• Automatic adjustment may not available for synchronization signal of C-SYNC and G-SYNC.
• Image may be distorted for several seconds during automatic adjustment. This is not a malfunction.
• For every supplied signal, adjustment is required.
• Automatic adjustment can be cancelled by pressing the MENU button during the course of automatic
adjustment.