Panasonic R410A service manual Air filter

Models: R410A

1 112
Download 112 pages 20.27 Kb
Page 72
Image 72
Air intake grille

Air filter

The air filter collects dust and other particles from the air and should be cleaned once every 6 months.

If the filter gets blocked, the efficiency of the air conditioner drops greatly.

NOTE

The frequency with which the filter should be cleaned depends on the environment in which the unit is used.

How to remove the filter

1.Slide the two latches of the air intake grille with your thumbs in the direction of the arrow to open the grille.

Latch

 

Ceiling

Air intake grille hinge

panel

 

2.Open the air intake grille downward.

Air intake grille

3.Press the tabs on both sides of the air filter (indicated with marks on the grill) to release the filter, and then, lift and pull the filter up and out using the tabs to remove it.

Safety cord

Air filter

4.Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it.

5.Insert the filter correctly again inside the grille, close the grille letting the latches slide towards the outside and fix again the latch.

How to remove the air intake grille

1.Open the air intake grille.

2.Detach the safety cord from the frame (remember to attach it again after cleaning or maintenance).

3.Hold on the air intake grille and pull it towards you to detach the two air intake grille hinges.

4.Clean the grille gently using a soft sponge, or the like. Then dry it with care.

Neutral detergent may be used to remove stubborn dirt. Then rinse thoroughly with water and dry it.

Air intake grille hinge

Safety cord

• When cleaning the air filter, never

CAUTION remove the safety cord. If it is necessary to remove it for servicing and maintenance inside, be sure to reinstall the safety cord securely (hook on the grille side) after the work.

When the air intake grille has been opened, rotating parts (such as the fan), electrically charged areas, etc. will be exposed in the unit’s opening. Bear in mind the dangers that these parts and areas pose, and proceed with the work carefully.

Periodically check the outdoor unit to see if the air outlet or air intake is clogged with dirt or soot.

Care: After a prolonged idle period

Check the indoor and outdoor unit air intakes and outlets for blockage; if there is a blockage, remove it.

Care: Before a prolonged idle period

Operate the fan for half a day to dry out the inside.

Disconnect the power supply and also turn off the circuit breaker.

Clean the air filter and replace it in its original position.

Outdoor unit internal components must be checked and cleaned periodically.

Contact your local dealer for this service.

14

Page 72
Image 72
Panasonic R410A service manual Air filter

R410A specifications

Panasonic R410A is a refrigerant that has gained significant popularity in the air conditioning and refrigeration industry due to its favorable environmental properties and performance characteristics. Specifically designed to replace the harmful R22 refrigerant, which is being phased out due to its ozone-depleting potential, R410A offers a more eco-friendly alternative without compromising on efficiency or power.

One of the main features of R410A is its high energy efficiency. It operates at a higher pressure than R22, resulting in better heat transfer capabilities. This increased efficiency translates to lower energy consumption, making units using R410A more cost-effective in the long run. Additionally, R410A is known for its ability to provide excellent cooling performance even in high-temperature environments, making it suitable for a variety of applications, from residential air conditioning systems to commercial refrigeration units.

In terms of composition, R410A is a blend of two hydrofluorocarbons (HFCs), namely R32 and R125. This combination not only minimizes ozone depletion potential (ODP) but also reduces global warming potential (GWP) compared to older refrigerants. Panasonic has emphasized the importance of innovative technologies in its products, and R410A aligns perfectly with the company's commitment to developing sustainable solutions.

Panasonic also integrates advanced technologies to optimize the performance of R410A systems. For example, variable speed compressors, known as inverter technology, enhance system efficiency by adjusting the compressor's speed according to the cooling demand. This ensures that energy is only consumed when needed, further reducing operational costs.

Furthermore, R410A has a wide range of applications, including air conditioning systems, heat pumps, and chillers. Its versatility makes it a popular choice among manufacturers and consumers alike. The refrigerant is also compatible with existing R22 equipment, although specific retrofit procedures must be followed to ensure peak performance and reliability.

In conclusion, Panasonic R410A stands out as an innovative refrigerant choice in the HVAC industry, offering a combination of energy efficiency, environmentally friendly properties, and advanced technologies. As regulatory frameworks continue to tighten on greenhouse gas emissions, R410A and similar refrigerants are expected to play a crucial role in shaping a more sustainable future for air conditioning and refrigeration. Its high performance and lower environmental impact solidify its position as a leading refrigerant in contemporary cooling solutions.