To perform a V.52 test, follow these steps:
1.Activate the local loopback or remote loopback diagnostic.
2.Activate the test pattern. This may be done in one of two ways:
a.Enter c Test Pattern from the System Diagnostics/Statistics menu and toggle the <Spacebar> until the desired test pattern appears.
One of two result codes will appear to the right of the c Test Pattern listing:
OK Indicates that the received test pattern is
BE Indicates that there are errors in the test pattern (to deliberately insert errors in the pattern, toggle
d Error Insertion to ON).
b.Toggle the front panel switch to either PAT or PAT/E (Test Pattern with Error Injection).
APPENDIX A
PATTON MODEL 2701RC
| SPECIFICATIONS |
Network Data Rate: | 2.048 Mbps |
Network Connector: | |
Nominal Impedance: | 120 ohm (75 ohm available when using |
| Patton Model 1001RCM11575 rear |
| card) |
DTE Interface: | V.35 (DCE Orientation) X.21 (DCE or |
| DTE orientation), |
| |
Line Coding: | Selectable AMI or HDB3 |
Line Framing: | G.703 (Unframed) or G.704/G.732 |
| (Framed) |
CAS Multiframing: | Selectable On or Off |
Selectable On or Off | |
Clocking: | Internal, External, or Receive Recover |
DTE Data Rates: | 64, 128, 192, 256, 320,384, 448, 512, |
| 576, 640, 704, 768, 832, 896, 960, |
| 1024, 1088, 1152, 1216, 1280, 1344, |
| 1408, 1472, 1536, 1600, 1664, 1728, |
| 1792, 1856, 1920, 1984, 2048 kbps |
Time Slot Rate: | 64 kbps |
DS0 Start Position: | Arbitrary |
DS0 Mapping Position: | Contiguous or Arbitrary |
Diagnostics: | V.54 Loopback; V.52 Patterns: 511, |
| 2047, and QRSS |
Indicators: | Power, Transmit Data, Receive Data, |
| Alarm, Loss of Sync, Test Mode, Error |
Configuration: | Two |
| Control Port, or SNMP Managable |
Power Supply: | |
Humidity: | Up to 90% |
Temperature: | 0 to 70o C |
Dimensions: | 9.0 x 5.3 x 2.0 cm (3.5”L x 2.1”W x |
| 0.78”H) |