Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA •
www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
Pelco and the Pelco logo are registered trademarks of Pelco. ©Copyright 2005, Pelco. All rights reserved.
DLP is a registered trademark of Texas Instruments, Inc.
C2931M (7/05)PMCD750 DLP
DisplayRemovable On-Screen Code Chart
The PMCD750 will flash a sequence of red and amber lights on the screen to indicate current status or if a fault exists. Cut out these cards for convenient
referencing of the on-screen codes.
Condition Priority Each block represents 0.2 seconds
Starts with red;
lamp is off
Door open 1 RRR
See footnote 1
Power supply fan failed 2 RAmber
DLP fan failed 3 RAmber R
350V failed 4 R R Amber
Optical engine failed 5 R R Amber R
Lamp failed 6 RRRR
Lamp off (wait, auto off) 2 7R R Amber Amber
Wait (lamp off, cooling) 8 R R R R
Starts with
amber
Lamp off (lamp saver) 3 9Amber Amber R
Lamp off (ready to turn on) 10 Amber Amber
Lamp striking (starting) 11 Amber Amber Amber
Lamp on, no alarms 12 Amber on continuously
R = Red To show the code, press MONITOR button once.
1With Priority 1-6, to turn lamp on, cycle off, and then on. If Auto Codes in the Miscellaneous menu is checked, events with Priority 1-5 start the
on-screen code automatically.
2Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
3A Lamp On command from the remote or from RS-232 commands will turn lamp on.
Condition Priority Each block represents 0.2 seconds
Starts with red;
lamp is off
Door open 1 RRR
See footnote 1
Power supply fan failed 2 RAmber
DLP fan failed 3 RAmber R
350V failed 4 R R Amber
Optical engine failed 5 R R Amber R
Lamp failed 6 RRRR
Lamp off (wait, auto off) 2 7R R Amber Amber
Wait (lamp off, cooling) 8 R R R R
Starts with
amber
Lamp off (lamp saver) 3 9Amber Amber R
Lamp off (ready to turn on) 10 Amber Amber
Lamp striking (starting) 11 Amber Amber Amber
Lamp on, no alarms 12 Amber on continuously
R = Red To show the code, press MONITOR button once.
1With Priority 1-6, to turn lamp on, cycle off, and then on. If Auto Codes in the Miscellaneous menu is checked, events with Priority 1-5 start the
on-screen code automatically.
2Lamp Saver turned lamp off; lamp is cooling and will turn on at end of cooling period.
3A Lamp On command from the remote or from RS-232 commands will turn lamp on.