C695M-B (11/03) 27

ALARM SETUP

Highlight the ALARM SETUP option on the setup menu screen and press the ENTER button. The ALARM SETUP screen is shown in
Figure 14.
Figure 14. Alarm Setup Screen
NOTE: These settings only apply to how the DX3100 records alarmed channels.
ALARM ACTIVE Select the start and stop time for this alarm. This setting indicates the activation start and stop time for each day.
The time format is always 24-hour and the default is 0 to 24, that is, midnight to midnight.
ALARM
CONTACT TYPE Select the type of contact that is connected to the alarm input terminal: N/O (normally open) or N/C (normally
closed). The default is N/O.
RECORD MODE Set the recording behavior when this alarm is activated. The default is SET.
SET When the alarm is triggered, the unit records the alarmed channel at the full frame rate for
the number of seconds specified in the RECORD TIME field. The unit ignores any alarm
deactivation.
DURATION When the alarm is triggered, the unit records the alarmed channel at the full frame rate until
the alarm is deactivated.
Channels that are programmed for alarm recording have precedence over channels that are
not alarmed. When an alarm is triggered, the alarmed channel records at the per-image rate
entered in the RECORDER SETUP menu. If the ips setting is relatively high, the recorded
image rate of the alarmed channel approaches real-time viewing quality. If more than one
alarmed channel is triggered, the ips rate is shared equally among the alarmed channels. All
nonalarmed channel recording is halted for the duration of the alarm.
RECORD TIME SET only: Set the alarm record time for alarm activation. This setting ranges from 1 to 99 seconds. The default is
5seconds.
ALARM RELAY
OUT 1 Select ON to enable the first alarm relay output. If the alarm is activated, the unit closes alarm relay output 1 for
the duration of alarm activation. Select OFF to disable this relay output.
ALARM RELAY
OUT 2 Select ON to enable the second alarm relay output. If the alarm is activated, the unit closes alarm relay output 2 for
the duration of alarm activation. Select OFF to disable this relay output.
ALARM SETUP
ALARMEDCAMERA
ALARMCONTACT TYPE
RECORDMODE
RECORDTIME 5
1
ALARMRELAY OUT 1
ALARMRELAY OUT 2
:
:
:
:
:
:
:
N/O
OFF
OFF
sec (1-99)
to
024
ALARM2
ALARM3
ALARM4
ALARMACTIVE (24 HR)
ALARM1
SET
DURATION