SPECIFICATIONS

ELECTRICAL

Input Voltage:

 

 

 

 

 

 

 

LRD41A11-1

 

 

 

 

 

 

 

Input Voltage:

 

120 VAC

 

 

 

 

P/T Voltage:

 

120 VAC

 

 

 

 

Camera Voltage:

 

24 VAC or 120 VAC (selectable)

 

 

Enclosure Voltage:

120 VAC

 

 

 

 

LRD41A11-2

 

 

 

 

 

 

 

Input Voltage:

 

24 VAC

 

 

 

 

 

P/T Voltage:

 

24 VAC

 

 

 

 

 

Camera Voltage:

 

24 VAC

 

 

 

 

 

Enclosure Voltage:

24 VAC

 

 

 

 

 

LRD41A11-3

 

 

 

 

 

 

 

Input Voltage:

 

230 VAC

 

 

 

 

P/T Voltage:

 

120 VAC

 

 

 

 

Camera Voltage:

 

24 VAC or 230 VAC (selectable)

 

 

Enclosure Voltage:

230 VAC

 

 

 

 

Frequency:

 

60/50 Hz

 

 

 

 

Power Consumption:

5 VA

 

 

 

 

 

Video Input:

 

75 ohms terminating

 

 

Video Output:

 

75 ohms terminating

 

 

Video Bandwidth:

 

10 MHz

 

 

 

 

Video Gain:

 

Unity

 

 

 

 

 

Video Formats:

 

NTSC or PAL

 

 

 

 

Control Method:

 

Coaxitron, 15-bit protocol

 

 

Lens Output

 

 

 

 

 

 

 

Voltage:

 

6 VDC to 10 VDC

 

 

 

 

Current:

 

25 mA @ 10 VDC

 

 

 

 

 

 

 

100 mA @ 9 VDC

 

 

 

 

Operating Distances:

Cable distances are approximate according to cable type used. 75-ohm coax required.

 

 

 

 

 

 

 

Cable Type

 

 

Distance

 

Distance Using EA2000

 

RG59/U

 

750 ft

(229 m)

 

3,000 ft

(914 m)

 

RG6/U

 

1,000 ft

(305 m)

 

4,500 ft

(1,372 m)

 

RG11/U

 

1,500 ft

(457 m)

 

6,000 ft

(1,829 m)

 

RG15

 

 

 

 

8,000 ft

(2,438 m)

 

 

 

 

 

 

 

 

 

Fuse Values:

 

F1

 

F2

 

 

 

 

 

LRD/PANTILT

ENCLOSURE

 

 

LRD41A11-1

 

2 amp

 

2 amp

 

 

LRD41A11-2

 

5 amp

 

6.3 amp

 

 

LRD41A11-3

 

1 amp

 

1 amp

 

 

10