P/N 471048 Rev. E 2-7-01
22
SPA COM POOL TPROBE
OUT RETURN
24 VAC HILMT IGNITION MOD
EXT SWITCH
THERMOSTAT CIRCUIT BOARD
JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH
POOL/OFF/SPA
FRONT PANEL
THERMOSTAT SELECT SWITCH
TFUSE VALVE
PRESS
SPA COM POOL TPROBE
OUT RETURN
24 VAC HILMT IGNITION MOD
EXT SWITCH
THERMOSTAT CIRCUIT BOARD
JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH
POOL/
OFF/SPA
FRONT PANEL
THERMOSTAT SELECT SWITCH
TFUSE VALVE
REMOTE POOL/OFF/SPA
THERMOSTAT SELECT SWITCH
PRESS
WHT
GAS VALVE
ORN
WHT
HI-LIMIT
OFF
SPA
WHT
WHT
SHUT-OFF
SAFETY
SWITCH
PRESS
WHT
POOL
MINIMAX WIRING DIAGRAM
(MILLIVOLT) DUAL THERM
(HONEYWELL ELECTRONIC)
PILOT
GENERATOR
THERMA
L
CUT-OFF
TH PP
TH/PP
POT 1
THERMOSTAT BOARD
POT 2
TH/PP
PP
POT
SENSOR
SEN TH
WHT
IF ORIGINAL FACTORY WIRING MUST BE REPLACED,
INSTALLER MUST SUPPLY UL OR CSA (IF CANADA)
APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING.
THERMAL FUSE WIRING MUST BE REPLACED WITH
UL OR CSA (IF CANADA) APPROVED WIRE,
18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING.
INTERCONNECTING WIRING TO APPLIANCE MUST
CONFORM TO THE NATIONAL ELECTRICAL
CODE OR SUPERCEDING LOCAL (WIRING) CODES.
WHT
RED
Installation (contd.)