Installation and commissioning

3.02.02 With control unit P323 MS

Switch on the machine.

● Call up the input mode.

● Call up the service function.

By turning the balance wheel in the sewing direction, ascertain the number of incre- ments per turn (this maximum value appears under "POS" in the display before the rea- ding jumps back to "0".

● Call up the input mode.

● Call up parameter "721".

721 127

● Enter the calculated max. value.

● Conclude the input.

Switch off the machine.