Philips Semiconductors ISP1122
USB stand-alone hub
Product specification Rev. 03 — 29 March 2000 10 of 48
9397 750 07002 © Philips Electronics N.V. 2000. All rights reserved.

6.9 PLL clock multiplier

A 6 to 48 MHz clock multiplier Phase-Locked Loop (PLL) is integrated on-chip. This
allows for the use of low-cost 6 MHz crystals. The low crystal frequency also
minimizes Electro-Magnetic Interference (EMI). The PLL requires no external
components.

6.10 Overcurrent detection

An overcurrent detection circuit for downstream ports has been integrated on-chip. It
is self-reporting, resets automatically, has a low trip time and requires no external
components. Both individual and global overcurrent detection are supported.

6.11 I2C-bus interface

A basic serial I2C-bus interface (single master,100 kHz) is provided to read VID, PID
and configuration bits from an external I2C-bus EEPROM (e.g. Philips PCF8582 or
equivalent). At reset the ISP1122 reads 6 bytes of data from the external memory.
The I2C-bus interface timing complies with the standard mode of operation as
described in

The I

2

C-bus and how to use it

, order number 9398 393 40011.
7. Modes of operation
The ISP1122 has severalmodes of operation, each corresponding with a different pin
configuration. Modes are selected by means of pins INDV, OPTION and SP/BP, as
shown in Tab le 4.
[1] Port power switching: logic0 = ganged, logic 1 = individual.
[2] Power mode: logic0=bus-powered, logic1 = self-powered (or hybrid-powered).
[3] No overcurrent detection.
[4] No power switching.
Table 4: Mode selection
Mode INDV
[1] OPTION SP/BP
[2] PSWn/GLn
(n = 1 to 4) PSW5/GL5/GPSW OCn
(n = 1 to 4) OC5/GOC
0000GoodLink ganged power inactive global overcurrent
1001GoodLink ganged power inactive global overcurrent
2010GoodLink ganged power inactive[3] inactive [3]
3011GoodLink[4] GoodLink [4] inactive global overcurrent
4100individual power inactive individual
overcurrent inactive
5101individual power individual power individual
overcurrent individual
overcurrent
6110individual power inactive inactive[3] inactive [3]
7111GoodLink[4] GoodLink [4] individual
overcurrent individual
overcurrent