Philips P-5760-A manual Ordering and Shipping Data

Models: P-5760-A

1 2
Download 2 pages 54.85 Kb
Page 2
Image 2
Ordering and Shipping Data

Philips Lighting Company

www.philips.com

Philips Lighting

200 Franklin Square Drive

 

281 Hillmount Road

P.O. Box 6800

 

Markham, Ontario

Somerset, NJ 08875-6800

 

Canada L6C 2S3

1-800-555-0050

 

1-800-555-0050

A Division of Philips Electronics North America Corporation

A Division of Philips Electronics Ltd.

Printed in USA 10/08

P-5760-A

 

Philips Halogen Long Life IR PAR Lamps (NOTE:These lamps are 130V lamps run on 120V)

Electrical,Technical and Ordering Data (Subject to change without notice)

 

Product

Ordering

 

 

 

Pkg

 

 

Bulb

 

 

 

Rated Avg.

Approx.

 

 

Class

MOL

 

Number

Code

 

Watts

Volts

Qty.

Description

Type

 

 

Base

Life (Hrs.)1

MBCP2

Lumens

Filament

(In.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Halogen Long Life IR PAR30 Short Neck Featuring Halogen Infrared Technology and WISO Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13850-3

45PAR30S/IRC/HAL/SP10

45

120

15

Spot 10°

PAR-30S

 

Medium

 

6000

8560

 

650

C, CC-8

358

13851-1

45PAR30S/IRC/HAL/FL25

45

120

15

Flood 25°

PAR-30S

 

Medium

 

6000

2340

 

650

C, CC-8

358

13852-9

45PAR30S/IRC/HAL/WFL40

45

120

15

Wide Flood 40°

PAR-30S

 

Medium

 

6000

1050

 

650

C, CC-8

358

 

Halogen Long Life IR PAR38 Featuring Halogen Infrared Technology and DiOptic Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13919-6

45PAR38/IRC/HAL/SP10

45

120

12

Spot 10°

PAR-38

 

Medium

 

6000

8750

 

675

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13856-0

45PAR38/IRC/HAL/FL25

45

120

12

Flood 25°

PAR-38

 

Medium

 

6000

3000

 

675

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13857-8

45PAR38/IRC/HAL/WFL40

45

120

12

Wide Flood 40°

PAR-38

 

Medium

 

6000

1100

 

675

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13858-6

55PAR38/IRC/HAL/SP10

55

120

12

Spot 10°

PAR-38

 

Medium

 

6000

10,700

 

880

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13859-4

55PAR38/IRC/HAL/FL25

55

120

12

Flood 25°

PAR-38

 

Medium

 

6000

3650

 

880

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13860-2

55PAR38/IRC/HAL/WFL40

55

120

12

Wide Flood 40°

PAR-38

 

Medium

 

6000

1400

 

880

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13864-4

90PAR38/IRC/HAL/SP10

90

120

12

Spot 10°

PAR-38

 

Medium

 

6000

19,500

1650

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13865-1

90PAR38/IRC/HAL/FL25

90

120

12

Flood 25°

PAR-38

 

Medium

 

6000

7200

1650

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

13866-9

90PAR38/IRC/HAL/WFL40

90

120

12

Wide Flood 40°

PAR-38

 

Medium

 

6000

2500

1650

C, CC-8

5516

 

 

 

 

 

 

 

 

 

DiOptic Reflector

Skirted

 

 

 

 

 

 

 

 

 

Ordering and Shipping Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outer

 

Case

 

Case

 

SKUs

 

SKU

 

 

Case

 

 

Pallet

 

 

 

Product

SKU UPC

Bar Code

Case

Weight

 

Cube

Pallet

Per

Layers

Dimensions

 

Dimensions

 

Dimensions

 

 

 

Number

(0 46677-)

(5 0046677-)

Qty.

(lbs.)

(cu. ft.)

Qty.

Layer

High

(W x D x H) (In.)

(W x D x H) (In.)

(W x D x H) (In.)

 

Halogen Long Life IR PAR30 Short Neck Featuring Halogen Infrared Technology and WISO Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13850-3

13850 9

13850 4

15

8.0

 

0.52

1350

135

10

3.38 x 3.38 x 4

 

10.81 x 17.69 x 4.69

39.31 x 46.19 x 46.9

13851-1

13851 6

13851 1

15

8.0

 

0.52

1350

135

10

3.38 x 3.38 x 4

 

10.81 x 17.69 x 4.69

39.31 x 46.19 x 46.9

13852-9

13852 3

13852 8

15

8.0

 

0.52

1350

135

10

3.38 x 3.38 x 4

 

10.81 x 17.69 x 4.69

39.31 x 46.19 x 46.9

 

Halogen Long Life IR PAR38 Featuring Halogen Infrared Technology and DiOptic Reflector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13919-6

13919 3

13919 8

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

13856-0

13856 1

13856 6

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13857-8

13857 8

13857 3

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

13858-6

13858 5

13858 0

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13859-4

13859 2

13859 7

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

13860-2

13860 8

13860 3

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

13864-4

13864 6

13864 1

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

13865-1

13865 3

13865 8

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13866-9

13866 0

13866 5

12

10.6

 

0.84

720

180

4

4.31 x 4.31 x 5.44

9.06 x 13.56 x 11.88

40.68 x 45.3 x 47.52

 

1)Rated average life is the length of operation (in hours) at which point an average of 50% of the lamps will still be operational and 50% will not.

2)Maximum Beam Candlepower

To avoid deterioration of lampholder by heat, use only heat resistant lampholders or fixtures listed by a nationally recognized electrical testing organization for use with reflector or PAR lamps.

PAR HALOGEN CAUTION NOTICE: Before using bulb, see operating instructions on inside flap. Adherence to the operating instructions will reduce the risk of personal injury or fire.The filament capsule contained inside this glass bulb is pressurized, operates at high temperature and could unexpectedly shatter. Should the outer bulb break, particles of extremely hot glass could be discharged into the fixture and/or the surrounding environment, thereby creating a risk of personal injury or fire.

OPERATING INSTRUCTIONS: Before replacing, turn off power and let lamp cool to avoid electrical shock or burn.

For indoor or outdoor use. A weather-protected fixture is recommended for wet locations. Suitable for use in open fixtures. Do not exceed the maximum wattage rating of the fixture. Do not use if outer glass is scratched or broken since it may break during operation or removal. If outer glass breaks the lamp may continue to light, however, immediately discontinue use. Due to the heat that radiates from the bulb, do not use in close proximity to combustible materials or objects susceptible to drying or fading. Manage in accord with disposal laws.

Page 2
Image 2
Philips P-5760-A manual Ordering and Shipping Data